CoChat

Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model

Reilly, J. Patrick, Freeman, Vanda T., Larkin, Willard D. · 1985 · IEEE Transactions on Biomedical Engineering
Cited by 195

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

A model of myelinated nerve axon was used to study the initiation and propagation of action potentials for a variety of extracellular electrical stimuli. Frankenhaeuser-Huxley nonlinearities were incorporated at each of several nodes in a longitudinal array, and the extracellular current pulse was modeled as a spatial distribution of voltage disturbance along the membrane. Results from the model were compared to data from human sensory experiments and from animal electrophysiological experiments. Effects of polarity, electrode position, pulse duration, and biphasic oscillation frequency were examined. Biphasic pulses have higher excitation thresholds than monophasic pulses, provided the duration of a single phase is short relative to the time constant of the membrane depolarization process. The shapes of strength/duration curves from sensory experiments conform well to model predictions for monophasic stimuli. Strength/frequency curves derived from the model are similar to those from sensory stimulation with sinusoidal currents. The shapes of strength/frequency curves can be explained by membrane integration effects at high frequencies and membrane leakage effects at low frequencies. The model predicts lower thresholds for cathodal than for anodal stimulation: the predicted degree of polarity selectivity is confirmed by direct stimulation of axons in animal experiments, but is at variance with the selectivity found in human transcutaneous stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1985.325509

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 195

Metadata

Authors
Reilly, J. P., Freeman, V. T., & Larkin, W. D.
Venue
IEEE Transactions on Biomedical Engineering
Published
1985-12
Volume
BME-32
Issue
12
Pages
1001-1011
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2049325685
Cited by
195
References
20
FWCI
1.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model. https://app.cochat.ai/papers/10.1109/tbme.1985.325509
The paper
Reilly, J. P., Freeman, V. T., & Larkin, W. D. (1985). Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1985.325509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.