The DOI matches its Crossref record.
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Abstract
A three-dimensional diffuse reflectance equation for a two-layer tissue model was developed using photon diffusion theory. In this model, tissue was considered to consist of two homogeneous isotropically scattering layers whose scattering and absorption constants were expressed as a linear sum of those of whole blood and a blood-free tissue component; tissue hemoglobin content and oxygen saturation were then expressed in terms of these total tissue parameters. Reflectance predictions given by the two-layer equation were used to investigate the effects of various tissue and system parameters on the partial reflectance from the second tissue layer; among such parameters significantly affecting deep-layer reflectance are the tissues scattering constants, its geometry, and the geometry of the optical transducer. When the penetration depth of the incident photons is small compared with the thickness of the first layer, reflectance contributions from the second layer are negligible, and a single-layer approximation would be adequate; resultant reflectance errors range from 6 to 8 percent of the total reflectance, for source-detector separations in the range from 1 to 4 mm. However, when the photon penetration depth is large with respect to first-layer thickness, the effects of deep layers are both important and strongly dependent on transducer geometry; partial reflectances range to 50 percent of the total when the source-detector separation is 4 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Refractive index of some mammalian tissues using a fiber optic cladding method
Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989) · Applied Optics · doi:10.1364/ao.28.002297 · Cited by 522
Noninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
Metadata
- Authors
- Takatani, S., & Graham, M. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1979-12
- Volume
- BME-26
- Issue
- 12
- Pages
- 656-664
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1966739192
- Cited by
- 249
- References
- 0
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model. https://app.cochat.ai/papers/10.1109/tbme.1979.326455
- The paper
- Takatani, S., & Graham, M. D. (1979). Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1979.326455
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.