CoChat

Magnetic Study of the His-Purkinje Conduction System in Man

Farrell, David E., Tripp, John H., Norgren, Richard · 1980 · IEEE Transactions on Biomedical Engineering
Cited by 41

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

It has recently been suggested that depolarization of the entire His-Purkinje conduction system of the heart produces a characteristic waveform in the surface electrocardiogram. The magnetic probe offers a different and, in some respects, advantageous means of observing such waveforms, and extensive records of the surface magnetic field generated by the human heart have been obtained for four normal subjects. A first-order SQUID gradiometer was employed havinAthe lowest noise level yet reported in any biomagnetic study (6 X 10-15 T/√Hz). Using an on-line computer, 100 beat averages were taken at 49 positions over the chest on a 1 in square grid. The fields observed have a characteristic symmetry and provide support for the suggestion that events associated with depolarization of the conduction system may be observed at the surface of the torso.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1980.326646

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Farrell, D. E., Tripp, J. H., & Norgren, R.
Venue
IEEE Transactions on Biomedical Engineering
Published
1980-07
Volume
BME-27
Issue
7
Pages
345-350
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1963584794
Cited by
41
References
1
FWCI
4.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.