CoChat

A Procedure for Decomposing the Myoelectric Signal Into Its Constituent Action Potentials-Part II: Execution and Test for Accuracy

Lefever, Ronald S., Xenakis, Alan P., De Luca, Carlo J. · 1982 · IEEE Transactions on Biomedical Engineering
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The scheme for decomposing a myoelectric signal into its constituent motor unit action potential trains described in the paper [3] requires interaction from the human operator. In this paper, guidelines to be employed by the operator in assisting the computerized algorithms in identifying (classifying) a motor unit action potential are presented. The accuracy of the decomposition scheme was evaluated by decomposing a mathematically synthesized myoelectric signal. This signal was constructed by linearly superimposing eight mathematically generated motor unit action potential trains along with Gaussian noise. A skilled operator was able to decompose this signal with an accuracy of 99.8 percent, incurring one error in a total of 435 classifications. The decomposition reproducibility was evaluated by having two experienced operators independently decompose the same record of empirically obtained myoelectric signal. Their results were in total agreement for 479 motor unit action potential classifications belonging to five motor unit action potential trains. Up to eight motor unit action potential trains have been decomposed from one myoelectric signal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1982.324882

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 140

Metadata

Authors
Lefever, R. S., Xenakis, A. P., & De Luca, C. J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1982-03
Volume
BME-29
Issue
3
Pages
158-164
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2093695590
Cited by
140
References
1
FWCI
5.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.