Moving Dipole Inverse ECG and EEG Solutions
The DOI matches its Crossref record.
Abstract
This paper reviews and updates the single moving dipole (SMD) and two moving dipole (TMD) inverse electrocardiographic and electroencephalographic solutions. These inverse solutions are particularly appropriate when the electrical activity of the heart or brain may be represented by one or two well-localized foci. They attempt to match the measured body surface or evoked scalp potentials to potentials generated on the surface of a model of the intervening volume conductor by one or two moving current dipoles, respectively. The two alternative methods of solution are discussed initially. The first is a direct least-squares error match of measured and model-generated surface potentials, the second an indirect solution based on the least-squares error match of the potentials due to equivalent multipole series representations of the real and model sources, respectively. Next, brief reviews of moving dipole inverse solutions in the EEG and ECG fields are presented. Simulation studies, as well as experimental and clinical studies in animals and humans, are described. The Discussion section summarizes the optimum solution approaches that should be used in clinical EEG and ECG studies in man. It also cautions against the temptation to translate the numerical adequacy of inverse SMD and TMD solutions into physiological validity, without independent knowledge as to the nature of the underlying sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Electric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., & Sato, T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326056 · Cited by 334
Electrophysiological correlates of the BOLD signal for EEG-informed fMRI
Murta, T., Leite, M., Carmichael, D. W., Figueiredo, P., & Lemieux, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.22623 · Cited by 165
“In generalised epilepsies, commonly widespread spike-related BOLD decreases have been detected in the cortex [Gotman et al., 2005; Hamandi et al., 2006; Salek-Haddadi et al., 2003].”
BackgroundInvestigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model
Mäntynen, V., Konttila, T., & Stenroos, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7141 · Cited by 45
Metadata
- Authors
- Gulrajani, R. M., Roberge, F. A., & Savard, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1984-12
- Volume
- BME-31
- Issue
- 12
- Pages
- 903-910
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2032449521
- Cited by
- 71
- References
- 0
- FWCI
- 0.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.