The DOI matches its Crossref record.
Observations on the Use of Ferromagnetic Implants for Inducing Hyperthermia
Abstract
Magnetic induction heating of ferromagnetic implants can be used to produce highly localized hyperthermia in deep seated tumors. We discuss the physical parameters which characterize this method and give illustrations from initial clinical investigations in animals. The physical parameters studied include magnetic field strength, frequency, load size, field uniformity, coil designs, and the heating potential of implant materials and configurations. Calculations consistent with our experimental results predict a maximum heating frequency of the order of 500 kHz for large cross-sectional loads, such as the human abdomen, and 1.9 MHz for smaller loads, such as the human brain. An experlhnental technique is introduced for accurate quantitative evaluation of the heating potentials of ferromagnetic materials in a gelled phantom medium. These data are analyzed in terms of heating efficiency per unit implant length (ηL), which is itself a function of implant length, diameter, annealed state, and orientation with respect to the magnetic field. A spiral sheet coil design is described and recommendations are given for proper E-Field shielding of induction coils for clinical applications. A brief discussion of techniques of implanting the ferromagnetic materials is also given. Finally, several in vivo animal studies are presented to illustrate the use of the technique for treating tumors in pelvis, thorax, oral-pharynx, and brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medical application of functionalized magnetic nanoparticles
Ito, A., Shinkai, M., Honda, H., & Kobayashi, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.1 · Cited by 1,470
Magnetic bead handling on-chip: new opportunities for analytical applications
Gijs, M. A. M. (2004) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0010-y · Cited by 749
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Usable Frequencies in Hyperthermia with Thermal Seeds
Atkinson, W. J., Brezovich, I. A., & Chakraborty, D. P. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325372 · Cited by 496
Heating technology for malignant tumors: a review
Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1779357 · Cited by 422
Inductively Heated Shape Memory Polymer for the Magnetic Actuation of Medical Devices
Buckley, P. R., McKinley, G. H., Wilson, T. S., Small, W., Benett, W. J., Bearinger, J. P., McElfresh, M. W., & Maitland, D. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877113 · Cited by 361
Functional magnetic particles for medical application
Shinkai, M. (2002) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(02)80202-x · Cited by 343
Functional Magnetic Particles for Medical Application.
SHINKAI, M. (2002) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.94.606 · Cited by 331
Intracellular Hyperthermia for Cancer Using Magnetite Cationic Liposomes: An in vivo Study
Yanase, M., Shinkai, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T. (1998) · Japanese Journal of Cancer Research · doi:10.1111/j.1349-7006.1998.tb00586.x · Cited by 322
Zhao, W., Zhang, F., Leng, J., & Liu, Y. (2019) · Composites Science and Technology · doi:10.1016/j.compscitech.2019.107866 · Cited by 279
Metadata
- Authors
- Stauffer, P. R., Cetas, T. C., Fletcher, A. M., Deyoung, D. W., Dewhirst, M. W., Oleson, J. R., & Roemer, R. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1984-01
- Volume
- BME-31
- Issue
- 1
- Pages
- 76-90
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2013235250
- Cited by
- 166
- References
- 0
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.