Cited by 361Advanced Materials and MechanicsPolymer composites and self-healingShape Memory Alloy Transformations

Inductively Heated Shape Memory Polymer for the Magnetic Actuation of Medical Devices

Buckley, P.R., McKinley, G.H., Wilson, T.S., Small, W., Benett, W.J., Bearinger, J.P., McElfresh, M.W., Maitland, D.J.·2006·IEEE Transactions on Biomedical Engineering

Abstract

Presently, there is interest in making medical devices such as expandable stents and intravascular microactuators from shape memory polymer (SMP). One of the key challenges in realizing SMP medical devices is the implementation of a safe and effective method of thermally actuating various device geometries in vivo. A novel scheme of actuation by Curie-thermoregulated inductive heating is presented. Prototype medical devices made from SMP loaded with nickel zinc ferrite ferromagnetic particles were actuated in air by applying an alternating magnetic field to induce heating. Dynamic mechanical thermal analysis was performed on both the particle-loaded and neat SMP materials to assess the impact of the ferrite particles on the mechanical properties of the samples. Calorimetry was used to quantify the rate of heat generation as a function of particle size and volumetric loading of ferrite particles in the SMP. These tests demonstrated the feasibility of SMP actuation by inductive heating. Rapid and uniform heating was achieved in complex device geometries and particle loading up to 10% volume content did not interfere with the shape recovery of the SMP.

Integrity signals

Registry

Crossref · 10.1109/tbme.2006.877113

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The magnetic-active SME makes selective heating of specific device areas of SMPCs possible.

    “In addition, the magnetic-active SME makes selective heating of specific device areas of SMPCs possible [35,142,337,377,378].”
  • Major challenges for magnetically induced actuation are increase in inductive heating efficiency, applied frequencies should not exceed clinically usable window 50-100 kHz, and tailoring transition temperatures near body temperature for multi-shape polymers.

    “major challenges are still the increase in inductive heating efficiency [13,45] (the applied frequencies should not exceed the restrictive window of clinically usable frequencies (50-100 kHz) [216]), and in case of polymers with multi-shape capabilities the tailoring of transition temperatures in a region close to body temperature.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Buckley, P. R., McKinley, G. H., Wilson, T. S., Small, W., Benett, W. J., Bearinger, J. P., McElfresh, M. W., & Maitland, D. J.
Affiliations
  • Lawrence Livermore National Laboratory (US)
  • Massachusetts Institute of Technology (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
2006-10
Volume
53
Issue
10
Pages
2075-2083
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2152406599
Cited by
361
References
37
Citations by year
2026: 7 · 2025: 8 · 2024: 18 · 2023: 15 · 2022: 18 · 2021: 11 · 2020: 23 · 2019: 16 · 2018: 16 · 2017: 18 · 2016: 14 · 2015: 25 · 2014: 24 · 2013: 28 · 2012: 21
FWCI
36.80
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Biomedical Imaging and Bioengineering (R01EB000462)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
  • Physical Sciences › Materials Science › Materials Chemistry › Shape Memory Alloy Transformations
Keywords
shape memory polymers, induction heating, magnetic actuation, Ni-Zn ferrite, ferromagnetic particles, medical devices, expandable stents, Curie temperature, particle loading, shape recovery, heat generation
MeSH terms
Biocompatible Materials, Equipment and Supplies, Equipment Design, Hot Temperature, Magnetics, Materials Testing, Polymers, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review