The DOI matches its Crossref record; 163 of the 163 references it cites were found in a registry or an index.
Heating technology for malignant tumors: a review
Open accessAbstract
The therapeutic application of heat is very effective in cancer treatment. Both hyperthermia, i.e., heating to 39-45 °C to induce sensitization to radiotherapy and chemotherapy, and thermal ablation, where temperatures beyond 50 °C destroy tumor cells directly are frequently applied in the clinic. Achievement of an effective treatment requires high quality heating equipment, precise thermal dosimetry, and adequate quality assurance. Several types of devices, antennas and heating or power delivery systems have been proposed and developed in recent decades. These vary considerably in technique, heating depth, ability to focus, and in the size of the heating focus. Clinically used heating techniques involve electromagnetic and ultrasonic heating, hyperthermic perfusion and conductive heating. Depending on clinical objectives and available technology, thermal therapies can be subdivided into three broad categories: local, locoregional, or whole body heating. Clinically used local heating techniques include interstitial hyperthermia and ablation, high intensity focused ultrasound (HIFU), scanned focused ultrasound (SFUS), electroporation, nanoparticle heating, intraluminal heating and superficial heating. Locoregional heating techniques include phased array systems, capacitive systems and isolated perfusion. Whole body techniques focus on prevention of heat loss supplemented with energy deposition in the body, e.g., by infrared radiation. This review presents an overview of clinical hyperthermia and ablation devices used for local, locoregional, and whole body therapy. Proven and experimental clinical applications of thermal ablation and hyperthermia are listed. Methods for temperature measurement and the role of treatment planning to control treatments are discussed briefly, as well as future perspectives for heating technology for the treatment of tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498
Verwaal, V. J., van Ruth, S., de Bree, E., van Slooten, G. W., van Tinteren, H., Boot, H., & Zoetmulder, F. A. N. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.04.187 · Cited by 2,049
Thermal ablation of tumours: biological mechanisms and advances in therapy
Chu, K. F., & Dupuy, D. E. (2014) · Nature Reviews Cancer · doi:10.1038/nrc3672 · Cited by 1,988
(2012) · Hepatogastroenterology · doi:10.5754/hge12458 · Cited by 1,977
Maier-Hauff, K., Ulrich, F., Nestler, D., Niehoff, H., Wust, P., Thiesen, B., Orawa, H., Budach, V., & Jordan, A. (2011) · Journal of Neuro-Oncology · doi:10.1007/s11060-010-0389-0 · Cited by 1,429
Self-citationHyperthermic Intraperitoneal Chemotherapy in Ovarian Cancer
van Driel, W. J., Koole, S. N., Sikorska, K., Schagen van Leeuwen, J. H., Schreuder, H. W. R., Hermans, R. H. M., de Hingh, I. H. J. T., van der Velden, J., Arts, H. J., Massuger, L. F. A. G., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1708618 · Cited by 1,426
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
A Randomized Trial of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Lipsman, N., Ondo, W. G., Ghanouni, P., Kim, Y. G., Lee, W., Schwartz, M., Hynynen, K., Lozano, A. M., Shah, B. B., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1600159 · Cited by 1,167
Cited by
Rational Design of Biomaterials to Potentiate Cancer Thermal Therapy
Zhu, Y., Li, Q., Wang, C., Hao, Y., Yang, N., Chen, M., Ji, J., Feng, L., & Liu, Z. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00822 · Cited by 163
Present and future of metal nanoparticles in tumor ablation therapy
Lou, W., Xie, L., Xu, L., Xu, M., Xu, F., Zhao, Q., & Jiang, T. (2023) · Nanoscale · doi:10.1039/d3nr04362b · Cited by 33
Eryildiz, M., Karakus, A., Demirci, M., Altintas Kadirhan, O., & Eksi Altan, M. (2025) · Polymers for Advanced Technologies · doi:10.1002/pat.70133 · Cited by 25
Metadata
- Authors
- Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2020-01-01
- Volume
- 37
- Issue
- 1
- Pages
- 711-741
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W3037300073
- Cited by
- 422
- References
- 163
- FWCI
- 15.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heating technology for malignant tumors: a review. https://app.cochat.ai/papers/10.1080/02656736.2020.1779357
- The paper
- Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020). Heating technology for malignant tumors: a review. International Journal of Hyperthermia. https://doi.org/10.1080/02656736.2020.1779357
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.