CoChat

System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission

Hochmair, Erwin S. · 1984 · IEEE Transactions on Biomedical Engineering
Cited by 146

The DOI matches its Crossref record.

Abstract

A stable transcutaneous transmission of power and signal via two coupled coils with minimized dependence on the relative spacing of external and implanted coil is possible by employing "critical coupling" between implanted and external circuits. Optimizing coil geometries and preventing the RF output amplifier from saturating is necessary to approximately maintain critical coupling despite placement tolerances within a reasonable range. Based on these considerations a transcutaneous signal transmission system for an auditory prosthesis has been designed. This transmission system can also be used for several other stimulation purposes needing accurate control of stimulation parameters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1984.325404

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 146

Metadata

Authors
Hochmair, E. S.
Venue
IEEE Transactions on Biomedical Engineering
Published
1984-02
Volume
BME-31
Issue
2
Pages
177-186
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2076394149
Cited by
146
References
0
FWCI
2.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission. https://app.cochat.ai/papers/10.1109/tbme.1984.325404
The paper
Hochmair, E. S. (1984). System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1984.325404

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.