The DOI matches its Crossref record.
ECG Data Compression Using Fourier Descriptors
Abstract
The method of Fourier descriptors (FD's) is presented for ECG data compression. The two-lead ECG data are segmented into QRS complexes and S-Q intervals, expressed as a complex sequence, and are Fourier transformed to obtain the FD's. A few lower order descriptors symmetrically situated with respect to the dc coefficient represent the data in the Fourier (compressed) domain. While compression ratios of 10:1 are feasible for the S-Q interval, the clinical information requirements limit this ratio to 3:1 for the QRS complex. With an overall compression ratio greater than 7, the quality of the reconstructed signal is well suited for morphological studies. The method is resistant to noisy signals and is simple, requiring implementation of forward and inverse FFT. The results of compression of ECG data obtained from more than 50 subjects with rhythm and morphological abnormalities are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ECG data compression techniques-a unified approach
Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52340 · Cited by 681
Fetal ECG extraction from single-channel maternal ECG using singular value decomposition
Kanjilal, P. P., Palit, S., & Saha, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553712 · Cited by 314
Huang, H., Hu, S., & Sun, Y. (2019) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3341559 · Cited by 10
Metadata
- Authors
- Reddy, B. R. S., & Murthy, I. S. N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-04
- Volume
- BME-33
- Issue
- 4
- Pages
- 428-434
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2016943313
- Cited by
- 172
- References
- 0
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.