The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ECG data compression techniques-a unified approach
Abstract
A broad spectrum of techniques for electrocardiogram (ECG) data compression have been proposed during the last three decades. Such techniques have been vital in reducing the digital ECG data volume for storage and transmission. These techniques are essential to a wide variety of applications ranging from diagnostic to ambulatory ECG's. Due to the diverse procedures that have been employed, comparison of ECG compression methods is a major problem. Present evaluation methods preclude any direct comparison among existing ECG compression techniques. The main purpose of this paper is to address this issue and to establish a unified view of ECG compression techniques. ECG data compression schemes are presented in two major groups: direct data compression and transformation methods. The direct data compression techniques are: ECG differential pulse code modulation and entropy coding, AZTEC, Turning-point, CORTES, Fan and SAPA algorithms, peak-picking, and cycle-to-cycle compression methods. The transformation methods briefly presented, include: Fourier, Walsh, and K-L transforms. The theoretical basis behind the direct ECG data compression schemes are presented and classified into three categories: tolerance-comparison compression, differential pulse code modulation (DPCM), and entropy coding methods. The paper concludes with the presentation of a framework for evaluation and comparison of ECG compression schemes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Cited by
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
The weighted diagnostic distortion (WDD) measure for ECG signal compression
Zigei, Y., Cohen, A., & Katz, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880093 · Cited by 405
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
Sayadi, O., & Shamsollahi, M. B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921150 · Cited by 254
Huang, H., Hu, S., & Sun, Y. (2019) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3341559 · Cited by 10
Metadata
- Authors
- Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990-04
- Volume
- 37
- Issue
- 4
- Pages
- 329-343
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2155321485
- Cited by
- 681
- References
- 1
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG data compression techniques-a unified approach. https://app.cochat.ai/papers/10.1109/10.52340
- The paper
- Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A. (1990). ECG data compression techniques-a unified approach. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.52340
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.