Sensors for Use with Functional Neuromuscular Stimulation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Functional neuromuscular stimulation (FNS) designates artificially applied electrical activation of muscles to restore function lost as a result of neurological lesions. FNS prostheses are currently being designed to restore urinary bladder control, standing, walking, and hand function. All of these prostheses need sensors for interaction with the human users and the environment. This paper discusses each of these prostheses with special regard to the use of sensors and the design specifications that the sensors must meet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Cited by
Detection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185
“,c, IFMBE: 2001 goniometer signal could amplify the high frequency noise components. Rate gyroscopes offer an alternative method for monitoring human joint rotations. Previously, real-time detection of angles based on rate gyroscopes was limited due to the zero frequency offset when stationary ( MURATA trade literatur…”
MethodInfluentialChronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Metadata
- Authors
- Crago, P. E., Chizeck, H. J., Neuman, M. R., & Hambrecht, F. T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-02
- Volume
- BME-33
- Issue
- 2
- Pages
- 256-268
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2092346528
- Cited by
- 142
- References
- 2
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensors for Use with Functional Neuromuscular Stimulation. https://app.cochat.ai/papers/10.1109/tbme.1986.325808
- The paper
- Crago, P. E., Chizeck, H. J., Neuman, M. R., & Hambrecht, F. T. (1986). Sensors for Use with Functional Neuromuscular Stimulation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1986.325808
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.