The influence of model parameters on EEG/MEG single dipole source estimation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper deals with source localization and strength estimation based on EEG and MEG data. It describes an estimation method (inverse procedure) which uses a four-spheres model of the head and a single current dipole. The dependency of the inverse solution on model parameters is investigated. It is found that sphere radii and conductivities influence especially the strength of the EEG equivalent dipole and not its location or direction. The influence on the equivalent dipole of the gradiometer is investigated. In general the MEG produces better location estimates than the EEG whereas the reverse is found for the component estimates. An inverse solution simultaneously based on EEG and MEG data appears slightly better than the average of separate EEG and MEG solutions. Variances of parameter estimators which can be calculated on the basis of a linear approximation of the model, were tested by Monte Carlo simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Model Studies of the Magnetocardiogram
Grynszpan, F., & Geselowitz, D. B. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86034-5 · Cited by 226
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
Electrical neuroimaging based on biophysical constraints
Grave de Peralta Menendez, R., Murray, M. M., Michel, C. M., Martuzzi, R., & Gonzalez Andino, S. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.051 · Cited by 365
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349
Spatial filtering and neocortical dynamics: estimates of EEG coherence
Srinivasan, R., Nunez, P. L., & Silberstein, R. B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686789 · Cited by 325
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
Faria, P., Hallett, M., & Miranda, P. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066017 · Cited by 243
Error bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233
Source parameter estimation in inhomogeneous volume conductors of arbitrary shape
Oostendorp, T. F., & van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19859 · Cited by 226
Mathematical dipoles are adequate to describe realistic generators of human brain activity
de Munck, J. C., van Dijk, B. W., & Spekreijse, H. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8677 · Cited by 225
Goncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219
“812164 head must be known a priori, and it is known that the solution to the EEG IP is highly dependent on the values taken for these parameters ([9]–[15]).”
BackgroundZhang, Z. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/3/001 · Cited by 192
Mikuni, N., Nagamine, T., Ikeda, A., Terada, K., Taki, W., Kimura, J., Kikuchi, H., & Shibasaki, H. (1997) · NeuroImage · doi:10.1006/nimg.1997.0272 · Cited by 190
Electrophysiological correlates of the BOLD signal for EEG-informed fMRI
Murta, T., Leite, M., Carmichael, D. W., Figueiredo, P., & Lemieux, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.22623 · Cited by 165
“…as: (i) overde-termined (dipolar) models [e.g., Gulrajani et al., 1984; Homma et al., 1990; Kavanagh et al., 1978; Scherg and Von Cramon, 1986; Stok, 1987], based on the assumption that a small and known number of current sources can adequately model the surface measurements; or (ii)…”
Baillet, S., Riera, J. J., Marin, G., Mangin, J. F., Aubert, J., & Garnero, L. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/306 · Cited by 159
SQUID sensor array configurations for magnetoencephalography applications
Vrba, J., & Robinson, S. E. (2002) · Superconductor Science and Technology · doi:10.1088/0953-2048/15/9/201 · Cited by 126
Metadata
- Authors
- Stok, C. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1987-04
- Volume
- BME-34
- Issue
- 4
- Pages
- 289-296
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2143589385
- Cited by
- 146
- References
- 1
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.