Abstract
This paper (Part I of II) presents a novel control scheme with which an amputee commands an elbow prosthesis using myoelectric activity. By mimicking some important characteristics of the intact neuromuscular system, the proposed controller attempts to make the prosthesis respond as the natural elbow to both voluntary commands from the amputee and applied moments from the environment. Also presented is the description of a novel experiment for functionally assessing elbow prosthesis controllers. The experimental design calls for an amputee to perform a constrained motion task while operating a prosthesis capable of implementing a wide variety of controllers. Due to the nature of the constraint, the task emphasizes the prosthesis response to both inputs: voluntary commands and external moments. Application of the experiment to assessment of the proposed control scheme and the control scheme used in a state-of-the-art prosthesis is presented in Part II.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
The effects of length and stimulus rate on tension in the isometric cat soleus muscle
Rack, P. M. H., & Westbury, D. R. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008923 · Cited by 1,144
Cited by
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Metadata
- Authors
- Abul-Haj, C. J., & Hogen, N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990-11
- Volume
- 37
- Issue
- 11
- Pages
- 1025-1036
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2131440040
- Cited by
- 82
- References
- 2
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional assessment of control systems for cybernetic elbow prostheses. I. Description of the technique. https://app.cochat.ai/papers/10.1109/tbme.1990.1438510
- The paper
- Abul-Haj, C. J., & Hogen, N. (1990). Functional assessment of control systems for cybernetic elbow prostheses. I. Description of the technique. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1990.1438510
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.