Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Dynamical diseases of brain systems: different routes to epileptic seizures

Lopes da Silva, F.H., Blanes, W., Kalitzin, S.N., Parra, J., Suffczynski, P., Velis, D.N. · 2003 · IEEE Transactions on Biomedical Engineering

Abstract

In this overview, we consider epilepsies as dynamical diseases of brain systems since they are manifestations of the property of neuronal networks to display multistable dynamics. To illustrate this concept we may assume that at least two states of the epileptic brain are possible: the interictal state characterized by a normal, apparently random, steady-state electroencephalography (EEG) ongoing activity, and the ictal state, that is characterized by paroxysmal occurrence of synchronous oscillations and is generally called, in neurology, a seizure. The transition between these two states can either occur: 1) as a continuous sequence of phases, like in some cases of mesial temporal lobe epilepsy (MTLE); or 2) as a sudden leap, like in most cases of absence seizures. In the mathematical terminology of nonlinear systems, we can say that in the first case the system's attractor gradually deforms from an interictal to an ictal attractor. The causes for such a deformation can be either endogenous or external. In this type of ictal transition, the seizure possibly may be anticipated in its early, preclinical phases. In the second case, where a sharp critical transition takes place, we can assume that the system has at least two simultaneous interictal and ictal attractors all the time. To which attractor the trajectories converge, depends on the initial conditions and the system's parameters. An essential question in this scenario is how the transition between the normal ongoing and the seizure activity takes place. Such a transition can occur either due to the influence of external or endogenous factors or due to a random perturbation and, thus, it will be unpredictable. These dynamical changes may not be detectable from the analysis of the ongoing EEG, but they may be observable only by measuring the system's response to externally administered stimuli. In the special cases of reflex epilepsy, the leap between the normal ongoing attractor and the ictal attractor is caused by a well-defined external perturbation. Examples from these different scenarios are presented and discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2003.810703

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 281

Metadata

Authors
Lopes da Silva, F. H., Blanes, W., Kalitzin, S. N., Parra, J., Suffczynski, P., & Velis, D. N.
Venue
IEEE Transactions on Biomedical Engineering
Published
2003-05
Volume
50
Issue
5
Pages
540-548
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2123553271
Cited by
281
References
32
FWCI
4.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamical diseases of brain systems: different routes to epileptic seizures. https://app.cochat.ai/papers/10.1109/tbme.2003.810703
The paper
Lopes da Silva, F. H., Blanes, W., Kalitzin, S. N., Parra, J., Suffczynski, P., & Velis, D. N. (2003). Dynamical diseases of brain systems: different routes to epileptic seizures. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2003.810703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.