The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Evaluation of Spike-Detection Algorithms for a Brain-Machine Interface Application
Abstract
Real time spike detection is an important requirement for developing brain machine interfaces (BMIs). We examined three classes of spike-detection algorithms to determine which is best suited for a wireless BMI with a limited transmission bandwidth and computational capabilities. The algorithms were analyzed by tabulating true and false detections when applied to a set of realistic artificial neural signals with known spike times and varying signal to noise ratios. A design-specific cost function was developed to score the relative merits of each detector; correct detections increased the score, while false detections and computational burden reduced it. Test signals both with and without overlapping action potentials were considered. We also investigated the utility of rejecting spikes that violate a minimum refractory period by occurring within a fixed time window after the preceding threshold crossing. Our results indicate that the cost-function scores for the absolute value operator were comparable to those for more elaborate nonlinear energy operator based detectors. The absolute value operator scores were enhanced when the refractory period check was used. Matched-filter-based detectors scored poorly due to their relatively large computational requirements that would be difficult to implement in a real-time system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“PROTOTYPE brain machine interfaces (BMIs) have successfully used spike timing information from extracellular neural signals to actuate prosthetic devices [1], [2].”
MethodDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370
Corticonics: Neural Circuits of the Cerebral Cortex
Abeles, M. (1991) · Cambridge University Press eBooks · doi:10.1017/cbo9780511574566 · Cited by 1,345
On a simple algorithm to calculate the 'energy' of a signal
Kaiser, J. F. (2002) · International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1990.115702 · Cited by 1,173
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
(1971) · Elsevier eBooks · doi:10.1016/c2013-0-07634-7 · Cited by 894
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
A new interpretation of nonlinear energy operator and its efficacy in spike detection
Mukhopadhyay, S., & Ray, G. C. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661266 · Cited by 385
Kim, K. H., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.871415 · Cited by 229
A method for spike sorting and detection based on wavelet packets and Shannon's mutual information
Hulata, E., Segev, R., & Ben-Jacob, E. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00032-8 · Cited by 201
A 100-channel system for real time detection and storage of extracellular spike waveforms
Guillory, K. S., & Normann, R. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00076-x · Cited by 180
Automatic EEG analysis during long-term monitoring in the ICU
Agarwal, R., Gotman, J., Flanagan, D., & Rosenblatt, B. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00009-1 · Cited by 176
Chandra, R. B., & Optican, L. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568916 · Cited by 122
Optimal detection, classification, and superposition resolution in neural waveform recordings
Bankman, I. N., Johnson, K. O., & Schneider, W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238472 · Cited by 110
A totally automated system for the detection and classification of neural spikes
Yang, X., & Shamma, S. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7287 · Cited by 75
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A. (2000) · doi:10.1201/9781420039054-13 · Cited by 16
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A., Morizio, J., Chapin, J. K., Nicolelis, M. A. L., & Wolf, P. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.pt2 · Cited by 9
Self-citation
Cited by
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Mitra, P., & Bokil, H. (2007) · doi:10.1093/acprof:oso/9780195178081.001.0001 · Cited by 842
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Metadata
- Authors
- Obeid, I., & Wolf, P. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-06
- Volume
- 51
- Issue
- 6
- Pages
- 905-911
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2147946355
- Cited by
- 262
- References
- 18
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.