Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,540

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Direct Cortical Control of 3D Neuroprosthetic Devices

Taylor, Dawn M., Tillery, Stephen I. Helms, Schwartz, Andrew B.·2002·Science

Abstract

Three-dimensional (3D) movement of neuroprosthetic devices can be controlled by the activity of cortical neurons when appropriate algorithms are used to decode intended movement in real time. Previous studies assumed that neurons maintain fixed tuning properties, and the studies used subjects who were unaware of the movements predicted by their recorded units. In this study, subjects had real-time visual feedback of their brain-controlled trajectories. Cell tuning properties changed when used for brain-controlled movements. By using control algorithms that track these changes, subjects made long sequences of 3D movements using far fewer cortical units than expected. Daily practice improved movement accuracy and the directional tuning of these units.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/science.1070291

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 3

  1. Craggs M., Adv. Neurol. 10, 91 (1975).
  2. For review see
  3. We thank D. Moran for allowing us to adapt his base virtual reality program; W. Lyn for his recording assistance; and D. Weber for designing the EMG recording system. Supported by a Whitaker Foundation Fellowship a Philanthropic Education Organization scholarship and U.S. Public Health Service contract numbers N01-NS-6-2347 and N01-NS-9-2321. Supporting Online Material www.sciencemag.org/cgi/content/full/296/5574/1829/DC1 Materials and Methods Movies S1 to S3

Cited by

See all 1,540

Metadata

Authors
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B.
Venue
Science
Published
2002-06-07
Volume
296
Issue
5574
Pages
1829-1832
ISSN
  • 0036-8075 (ISSN-L)
  • 1095-9203
OpenAlex
W4253453051
Cited by
1,540
References
7
FWCI
27.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Cortical Control of 3D Neuroprosthetic Devices. https://app.cochat.ai/papers/10.1126/science.1070291
The paper
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002). Direct Cortical Control of 3D Neuroprosthetic Devices. Science. https://doi.org/10.1126/science.1070291

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.