The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
BCI Competition 2003—Data Set IIb: Enhancing P300 Wave Detection Using ICA-Based Subspace Projections for BCI Applications
Abstract
An algorithm based on independent component analysis (ICA) is introduced for P300 detection. After ICA decomposition, P300-related independent components are selected according to the a priori knowledge of P300 spatio-temporal pattern, and clear P300 peak is reconstructed by back projection of ICA. Applied to the dataset IIb of BCI Competition 2003, the algorithm achieved an accuracy of 100% in P300 detection within five repetitions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Dynamic Brain Sources of Visual Evoked Responses
Makeig, S., Westerfield, M., Jung, T.-P., Enghoff, S., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2002) · Science · doi:10.1126/science.1066168 · Cited by 1,630
Cited by
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Blankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537
Metadata
- Authors
- Xu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-06
- Volume
- 51
- Issue
- 6
- Pages
- 1067-1072
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2160634130
- Cited by
- 258
- References
- 3
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BCI Competition 2003—Data Set IIb: Enhancing P300 Wave Detection Using ICA-Based Subspace Projections for BCI Applications. https://app.cochat.ai/papers/10.1109/tbme.2004.826699
- The paper
- Xu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004). BCI Competition 2003—Data Set IIb: Enhancing P300 Wave Detection Using ICA-Based Subspace Projections for BCI Applications. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.826699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.