A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We have designed, fabricated, and characterized a microminiaturized "neuroport" for brain implantable neuroprosthesis applications, using an analog CMOS integrated circuit and a silicon based microelectrode array. An ultra-low power, low-noise CMOS preamplifier array with integral multiplexing was designed to accommodate stringent thermal and electrophysiological requirements for implantation in the brain, and a hybrid integration approach was developed to fabricate a functional microminiaturized neuroprobe device. Measurements showed that our fully scalable 16-channel CMOS amplifier chip had an average gain of 44 dB, bandwidth from 10 Hz to 7.3 kHz, and an equivalent input noise of approximately 9 microVrms with an average power consumption per preamplifier of 52 microW, which is consistent with simulation results. As a proof-of-concept demonstration, we have measured local field potentials from thalamocortical brain slices of rats, showing oscillatory behavior with an amplitude about 0.5 mV and a period ranging 80-120 ms. The results suggest that the hybrid integrated neuroport can form a prime platform for the development of a next level microminiaturized neural interface to the brain in a single implantable unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 2×
“THERE have been striking advances in the past two years in the development of recording techniques that have enabled the extraction of signals from the living brain to control rudimentary robotic devices [1], [2].”
BackgroundA low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · cited 2×
“The first successful effort to integrate amplifiers with a sensor probe that we are aware of was presented by Najafi and Wise [9] in 1986 and”
BackgroundMethod
Cited by
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
Self-citationAn implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
Self-citationThe 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
Metadata
- Authors
- Patterson, W. R., Song, Y.-K., Bull, C. W., Ozden, I., Deangellis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Donoghue, J. D., & Connors, B. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-10
- Volume
- 51
- Issue
- 10
- Pages
- 1845-1853
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2129003354
- Cited by
- 100
- References
- 3
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications. https://app.cochat.ai/papers/10.1109/tbme.2004.831521
- The paper
- Patterson, W. R., Song, Y.-K., Bull, C. W., Ozden, I., Deangellis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Donoghue, J. D., & Connors, B. W. (2004). A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.831521
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.