The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Skin Cancer Identification Using Multifrequency Electrical Impedance—A Potential Screening Tool
Abstract
Electrical bio-impedance can be used to assess skin cancers and other cutaneous lesions. The aim of this study was to distinguish skin cancer from benign nevi using multifrequency impedance spectra. Electrical impedance spectra of about 100 skin cancers and 511 benign nevi were measured. Impedance of reference skin was measured ipsi-laterally to the lesions. The impedance relation between lesion and reference skin was used to distinguish the cancers from the nevi. It was found that it is possible to separate malignant melanoma from benign nevi with 75% specificity at 100% sensitivity, and to distinguish nonmelanoma skin cancer from benign nevi with 87% specificity at 100% sensitivity. The power of skin cancer detection using electrical impedance is as good as, or better than, conventional visual screening made by general practitioners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Clinical dermatology, a color guide to diagnosis and therapy
Habif, T. P. (1985) · Cited by 293
Micromachined electrodes for biopotential measurements
Griss, P., Enoksson, P., Tolvanen-Laakso, H. K., Merilainen, P., Ollmar, S., & Stemme, G. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.911086 · Cited by 239
Self-citationRelation between tissue structure and imposed electrical current flow in cervical neoplasia
Brown, B. H., Tidy, J. A., Boston, K., Blackett, A. D., Smallwood, R. H., & Sharp, F. (2000) · The Lancet · doi:10.1016/s0140-6736(99)09095-9 · Cited by 205
The Actinic (Solar) Keratosis: A 21st-Century Perspective
Fu, W., & Cockerell, C. J. (2003) · Archives of Dermatology · doi:10.1001/archderm.139.1.66 · Cited by 158
Blad, B., & Baldetorp, B. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/4a/015 · Cited by 126
Cited by
Bioelectric controls of cell proliferation: Ion channels, membrane voltage and the cell cycle
Blackiston, D. J., McLaughlin, K. A., & Levin, M. (2009) · Cell Cycle · doi:10.4161/cc.8.21.9888 · Cited by 468
The Evolution of Melanoma Diagnosis: 25 Years Beyond the ABCDs
Rigel, D. S., Russak, J., & Friedman, R. (2010) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20074 · Cited by 420
Lobikin, M., Chernet, B., Lobo, D., & Levin, M. (2012) · Physical Biology · doi:10.1088/1478-3975/9/6/065002 · Cited by 166
Chernet, B. T., & Levin, M. (2013) · Disease Models & Mechanisms · doi:10.1242/dmm.010835 · Cited by 148
Metadata
- Authors
- Aberg, P., Nicander, I., Hansson, J., Geladi, P., Holmgren, U., & Ollmar, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-12
- Volume
- 51
- Issue
- 12
- Pages
- 2097-2102
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2117465127
- Cited by
- 301
- References
- 22
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin Cancer Identification Using Multifrequency Electrical Impedance—A Potential Screening Tool. https://app.cochat.ai/papers/10.1109/tbme.2004.836523
- The paper
- Aberg, P., Nicander, I., Hansson, J., Geladi, P., Holmgren, U., & Ollmar, S. (2004). Skin Cancer Identification Using Multifrequency Electrical Impedance—A Potential Screening Tool. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.836523
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.