The DOI matches its Crossref record.
Micromachined electrodes for biopotential measurements
Abstract
We describe the microfabrication, packaging and testing of a micromachined dry biopotential electrode, (i.e., where electrolytic gel is not required). It consists of an array of micro-dimensioned, very sharp spikes, (i.e., needles) designed for penetration of human skin which circumvent high impedance problems associated with layers of the outer skin. The spikes are etched in silicon by deep reactive ion etching and are subsequently covered with a silver-silverchloride (Ag-AgCl) double layer. The electrode-skin-electrode impedance of dry spiked electrodes having a size of 4/spl times/4 mm/sup 2/ is reduced compared to standard electrodes using electrolytic gel and having a comparable size. Recorded low amplitude biopotentials resulting from the activity of the brain, (i.e., EEG signals) are of high quality, even for spiked electrodes as small as 2/spl times/2 mm/sup 2/. The spiked electrode offers a promising alternative to standard electrodes in biomedical applications and is of interest in research of new biomedical methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Skin Cancer Identification Using Multifrequency Electrical Impedance—A Potential Screening Tool
Aberg, P., Nicander, I., Hansson, J., Geladi, P., Holmgren, U., & Ollmar, S. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836523 · Cited by 301
Self-citation
Metadata
- Authors
- Griss, P., Enoksson, P., Tolvanen-Laakso, H. K., Merilainen, P., Ollmar, S., & Stemme, G.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2001-03
- Volume
- 10
- Issue
- 1
- Pages
- 10-16
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2145121303
- Cited by
- 239
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micromachined electrodes for biopotential measurements. https://app.cochat.ai/papers/10.1109/84.911086
- The paper
- Griss, P., Enoksson, P., Tolvanen-Laakso, H. K., Merilainen, P., Ollmar, S., & Stemme, G. (2001). Micromachined electrodes for biopotential measurements. Journal of Microelectromechanical Systems. https://doi.org/10.1109/84.911086
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.