Multielectrode Microprobes for Deep-Brain Stimulation Fabricated With a Customizable 3-D Electroplating Process
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Although deep-brain stimulation (DBS) can be used to improve some of the severe symptoms of Parkinson's disease (e.g., Bradykinesia, rigidity, and tremors), the mechanisms by which the symptoms are eliminated are not well understood. Moreover, DBS does not prevent neurodegeneration that leads to dementia or death. In order to fully investigate DBS and to optimize its use, a comprehensive long-term stimulation study in an animal model is needed. However, since the brain region that must be stimulated, known as the subthalamic nucleus (STN), is extremely small (500 microm x 500 microm x 1 mm) and deep within the rat brain (10 mm), the stimulating probe must have geometric and mechanical properties that allow accurate positioning in the brain, while minimizing tissue damage. We have designed, fabricated, and tested a novel micromachined probe that is able to accurately stimulate the STN. The probe is designed to minimize damage to the surrounding tissue. The probe shank is coated with gold and the electrode interconnects are insulated with silicon nitride for biocompatibility. The probe has four platinum electrodes to provide a variety of spatially distributed stimuli, and is formed in a novel 3-D plating process that results in a microwire like geometry (i.e., smoothly tapering diameter) with a corresponding mechanically stable shank.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · cited 1×
“lene [15], [33], [35], [36].”
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 1×
“The most common micromachined electrode arrays are constructed out of silicon as the structural support layer, silicon nitride and silicon dioxide as the insulator, and iridium or gold as the electrode material [14]–[18].”
BackgroundRegeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 168
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Cited by
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
Kwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36
Metadata
- Authors
- Motta, P. S., & Judy, J. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-05
- Volume
- 52
- Issue
- 5
- Pages
- 923-933
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2143126434
- Cited by
- 67
- References
- 4
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.