The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Abstract
A low electrode-electrolyte impedance interface is critical in the design of electrodes for biomedical applications. To design low-impedance interfaces a complete understanding of the physical processes contributing to the impedance is required. In this work a model describing these physical processes is validated and extended to quantify the effect of organic coatings and incubation time. Electrochemical impedance spectroscopy has been used to electrically characterize the interface for various electrode materials: platinum, platinum black, and titanium nitride; and varying electrode sizes: 1 cm2, and 900 microm2. An equivalent circuit model comprising an interface capacitance, shunted by a charge transfer resistance, in series with the solution resistance has been fitted to the experimental results. Theoretical equations have been used to calculate the interface capacitance impedance and the solution resistance, yielding results that correspond well with the fitted parameter values, thereby confirming the validity of the equations. The effect of incubation time, and two organic cell-adhesion promoting coatings, poly-L-lysine and laminin, on the interface impedance has been quantified using the model. This demonstrates the benefits of using this model in developing better understanding of the physical processes occurring at the interface in more complex, biomedically relevant situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atlas of Electrochemical Equilibria in Aqueous Solutions
Pourbaix, M. (1974) · doi:10.5006/37502 · Cited by 8,026
Impedance Spectroscopy: Theory, Experiment, and Applications
(2005) · Wiley eBooks · doi:10.1002/0471716243 · Cited by 5,322
Armstrong, R. D. (1988) · Electrochimica Acta · doi:10.1016/0013-4686(88)80076-8 · Cited by 1,945
Kinetics of rapid electrode reactions
Randles, J. E. B. (1947) · Discussions of the Faraday Society · doi:10.1039/df9470100011 · Cited by 1,884
Electrocatalysts for O2 reduction
Yeager, E. (1984) · Electrochimica Acta · doi:10.1016/0013-4686(84)85006-9 · Cited by 1,222
Wegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769
Ueber das Verhalten sogenannter unpolarisirbarer Elektroden gegen Wechselstrom
Warburg, E. (1899) · Annalen der Physik · doi:10.1002/andp.18993030302 · Cited by 468
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS*
Schwan, H. P. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20349.x · Cited by 368
Mirsky, V. M., Riepl, M., & Wolfbeis, O. S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00053-5 · Cited by 289
Bockris, J. O., & Reddy, A. K. N. (1970) · Springer eBooks · doi:10.1007/978-1-4615-7464-4 · Cited by 275
The linear and non-linear electrical properties of the electrode-electrolyte interface
McAdams, E. T., Lackermeier, A., McLaughlin, J. A., Macken, D., & JOSSINET, J. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96795-z · Cited by 243
Linear and nonlinear electrode polarization and biological materials
Schwan, H. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368531 · Cited by 233
CMOS microelectrode array for the monitoring of electrogenic cells
Heer, F., Franks, W., Blau, A. W., Taschini, S., Ziegler, C., Hierlemann, A. R., & Baltes, H. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.006 · Cited by 181
Self-citationGross, G., Rhoades, B. K., Reust, D. L., & Schwalm, F. (1993) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(93)90001-8 · Cited by 154
Cell based biosensors using microelectrodes
Borkholder, D. A. (1998) · Cited by 150
Onaral, B., & Schwan, H. P. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442796 · Cited by 131
Electrical stimulation of the auditory nerve: direct current measurement in vivo
Huang, C., Shepherd, R. K., P.M. Center, Seligman, P., & Tabor, B. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.752943 · Cited by 114
Tykocinski, M., Duan, Y., Tabor, B., & Cowan, R. (2001) · Hearing Research · doi:10.1016/s0378-5955(01)00320-3 · Cited by 99
Janders, M., Egert, U., Stelzle, M., & Nisch, W. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656936 · Cited by 90
An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices.
Thiebaud, P., Beuret, C., Koudelka-Hep, M., Bove, M., Martinoia, S., Grattarola, M., Jahnsen, H., Rebaudo, R., Balestrino, M., Zimmer, J., et al. (1999) · Biosensors & bioelectronics · doi:10.1016/s0956-5663(98)00098-0 · Cited by 68
Davies, P. W. (1962) · Elsevier eBooks · doi:10.1016/b978-1-4831-6742-8.50010-0 · Cited by 58
Electrode-electrolyte interface impedance: Experiments and model
Bates, J. B., & Chu, Y. T. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368536 · Cited by 37
CMOS monolithic microelectrode array for stimulation and recording of natural neural networks
Franks, W., Heer, F., McKay, I., Taschini, S., Sunier, R., Hagleitner, C., Hierlemann, A. R., & Baltes, H. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216927 · Cited by 31
Self-citationChou, H. A., Zavitz, D. H., & Ovadia, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00116-1 · Cited by 20
Heuschkel, M. O. (2001) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-2370 · Cited by 12
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Ripples in the medial temporal lobe are relevant for human memory consolidation
Axmacher, N., Elger, C. E., & Fell, J. (2008) · Brain · doi:10.1093/brain/awn103 · Cited by 372
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Metadata
- Authors
- Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-07
- Volume
- 52
- Issue
- 7
- Pages
- 1295-1302
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2126012359
- Cited by
- 659
- References
- 26
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.