The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Motion Estimation in Beating Heart Surgery
Abstract
Minimally invasive beating-heart surgery offers substantial benefits for the patient, compared to conventional open surgery. Nevertheless, the motion of the heart poses increased requirements to the surgeon. To support the surgeon, algorithms for an advanced robotic surgery system are proposed, which offer motion compensation of the beating heart. This implies the measurement of heart motion, which can be achieved by tracking natural landmarks. In most cases, the investigated affine tracking scheme can be reduced to an efficient block matching algorithm allowing for realtime tracking of multiple landmarks. Fourier analysis of the motion parameters shows two dominant peaks, which correspond to the heart and respiration rates of the patient. The robustness in case of disturbance or occlusion can be improved by specially developed prediction schemes. Local prediction is well suited for the detection of single tracking outliers. A global prediction scheme takes several landmarks into account simultaneously and is able to bridge longer disturbances. As the heart motion is strongly correlated with the patient's electrocardiogram and respiration pressure signal, this information is included in a novel robust multisensor prediction scheme. Prediction results are compared to those of an artificial neural network and of a linear prediction approach, which shows the superior performance of the proposed algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detecting strange attractors in turbulence
Takens, F. (1981) · Lecture Notes in Mathematics · doi:10.1007/bfb0091924 · Cited by 10,459 · cited 1×
“If is smooth at least at the second derivative , this can be achieved with the help of Takens Theorem [ 27 ].”
Research works printed but not linked: 31
- Falk, 1999, Endoscopic coronary artery bypass grafting on the beating heart using a computer enhanced telemanipulation system, Heart Surg. Forum, 2, 199
- Kodera, 2001, Closed chest CABG on the beating heart with a computer-enhanced articulating system: Case report, Heart Surg. Forum, 4, 305
- Sackier, 1995, Computer-Integrated Surgery, 577
- 10.1109/robot.2000.844121 · DOI · Paper page
- 10.1016/S0003-4975(00)02003-8 · doi:10.1016/s0003-4975(00)02003-8
- 10.1055/s-2002-34585 · doi:10.1055/s-2002-34585
- 10.1055/s-2000-6902 · doi:10.1055/s-2000-6902
- Koransky, 2003, Quantification of mechanical stabilization for the performance of off-pump coronary artery surgery, Heart Surg. Forum, 6, 224
- 10.1016/S0003-4975(02)03734-7 · doi:10.1016/s0003-4975(02)03734-7
- 10.1016/1062-1458(96)86754-7 · doi:10.1016/1062-1458(96)86754-7
- Koransky, 2001, Quantification of mechanical stabilization for the performance of off-pump coronary artery surgery, Heart Surg. Forum, 4, 125
- Salvendy, 1987, Wiley, 182
- 10.1016/S0003-4975(02)03457-4 · DOI
- 10.1016/S0003-4975(03)01058-0 · DOI
- 10.1016/S1474-6670(17)37999-5 · doi:10.1016/s1474-6670(17)37999-5
- 10.1109/IROS.2000.894664 · doi:10.1109/iros.2000.894664
- Preusche, 2002, Teleoperation concepts in minimally invasive surgery, Contr. Eng. Practice J., 10
- 10.1109/ROBOT.2001.932903 · doi:10.1109/robot.2001.932903
- 10.1109/ROBOT.2004.1307163 · doi:10.1109/robot.2004.1307163
- Stöffler, 2001, Realzeitfähige Bestimmung und Interpretation des optischen Flusses zur Navigation mit einem mobilen Roboter
- 10.1007/BFb0015547 · DOI
- 10.1109/ICCV.1995.466872 · DOI
- 10.1109/TMI.2003.809090 · doi:10.1109/tmi.2003.809090
- 10.1109/42.310876 · doi:10.1109/42.310876
- 10.1117/12.466926 · doi:10.1117/12.466926
- 10.1007/3-540-45404-7_8 · doi:10.1007/3-540-45404-7_8
- Weigend, 1993, Time Series Prediction. Forecasting the Future and Understanding the Past
- Kantz, 1997, Nonlinear Time Series Analysis
- Ortmaier, Robust motion estimation in robotic surgery on the beating heart, 206
- Wei, 1997, Real-time visual servoing for laparoscopic surgery, IEEE Eng. Med. Biol. Mag., 16, 40, 10.1109/51.566151 · DOI
- 10.1002/acs.4480080502 · doi:10.1002/acs.4480080502
Cited by
Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“Such technologies 40,42,45,46 are mainly developed to remove (damp out or compensate) the tremor and assist patients in performing their voluntary movements 41,47–49 .”
Background
Metadata
- Authors
- Ortmaier, T., Groger, M., Boehm, D. H., Falk, V., & Hirzinger, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-10
- Volume
- 52
- Issue
- 10
- Pages
- 1729-1740
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2130643598
- Cited by
- 187
- References
- 1
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.