Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 239

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Noninvasive Measurement of Heartbeat, Respiration, Snoring and Body Movements of a Subject in Bed via a Pneumatic Method

Watanabe, K., Watanabe, T., Watanabe, H., Ando, H., Ishikawa, T., Kobayashi, K.·2005·IEEE Transactions on Biomedical Engineering

Abstract

We have developed a noninvasive pneumatics-based system by which to measure heartbeat, respiration, snoring, and body movements of a subject in bed. A thin, air-sealed cushion is placed under the bed mattress of the subject and the small movements attributable to human automatic vital functions are measured as changes in pressure using a pressure sensor having an almost flat frequency response from 0.1 to 5 kHz and a sensitivity of 56 mV/Pa. Using the newly developed system, heartbeat, respiration, apnea, snoring and body movements are clearly measured. In addition, the optimal signal-to-noise (S/N) ratio by which to evaluate the reliability of the heart rate measurement is presented. Heart rates were measured for four different body postures, 13 different subjects, four different bed mattresses, and three different sensor positions. For these measurements, the S/N ratios ranged from 15.9 to 23.5 dB, and so were determined to be reliable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2005.857637

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Watanabe, K., Watanabe, T., Watanabe, H., Ando, H., Ishikawa, T., & Kobayashi, K.
Venue
IEEE Transactions on Biomedical Engineering
Published
2005-12
Volume
52
Issue
12
Pages
2100-2107
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2137619789
Cited by
239
References
1
FWCI
5.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.