Microelectrode Array for Chronic Deep-Brain Microstimulation and Recording
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have developed an array of microelectrodes that is suitable for long-term implantation into the subthalamic nucleus (STN) or the globus pallidus and is able to record from single neurons, as well as deliver localized microstimulation. This device can be used to investigate the mechanisms by which deep brain stimulation can ameliorate the symptoms of Parkinson's disease and other movement disorders, and also may be the basis for a new clinical tool for the treatment of Parkinson's disease, by capitalizing on the high spatial specificity of intranuclear microstimulation. The array includes 16 activated iridium microelectrodes, 5-6 mm in length, within a cluster approximately 1.8 mm in diameter. We have fabricated the array using materials carrying the USP Category VI classification, and we have developed an apparatus and a procedure for implanting the microelectrode arrays into the deep brain. Ten arrays have been implanted into the STN of domestic cats, and one into the internal segment of the globus pallidus, for 140-415 days. During that time, we were able to record action potentials from individual neurons, on 4 to 8 of the 16 channels. The microelectrode' active surface areas ranged from 500 to 2000 microm2. Controlled-current pulses, 26.5 microA in amplitude and 150 micros/phase in duration (4 nC/phase) were used to excite neurons in the cat's STN. In addition to direct activation, the stimulus modulated the neuronal activity over a distance of at least 1.2 mm from the site of stimulation. These parameters did not induce histologically detectable changes around the tip sites after 35 hours of stimulation at 100 Hz (7 hours of stimulation per day, on 5 successive days), if the electrode' active surface area was 1000 microm2 or greater.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep brain stimulation and essential tremor
Lyons, K. E., & Pahwa, R. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200401000-00002 · Cited by 98
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1994) · Hearing Research · doi:10.1016/0378-5955(94)90258-5 · Cited by 80
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
“Studies referenced (Hambrecht 1995, McCreery et al 2006, 2010, 1986, 1992, 1994, 1997, 2000, McCreery and Shepherd 2006).”
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Neuromodulation for Brain Disorders: Challenges and Opportunities
Johnson, M. D., Lim, H. H., Netoff, T. I., Connolly, A. T., Johnson, N., Roy, A., Holt, A., Lim, K. O., Carey, J. R., Vitek, J. L., et al. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244890 · Cited by 251
“taining radially segmented [27] or multiprong electrodes [28] will enable clinicians to more precisely sculpt electric fields”
BackgroundKozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 190
Sputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M., & Rizzo, J. F. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188
“4 mC/cm(2) are expected.(5) Stimulation studies with retinal surface electrodes have identified perceptual thresholds in humans that vary from 24 nC to [1 lC per phase.”
BackgroundTechnology Insight: future neuroprosthetic therapies for disorders of the nervous system
Normann, R. A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0556 · Cited by 167
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Suitability of NFC for Medical Device Communication and Power Delivery
Freudenthal, E., Herrera, D., Kautz, F., Natividad, C., Ogrey, A., Sipla, J., Sosa, A., Betancourt, C., & Estevez, L. (2007) · 2007 IEEE Dallas Engineering in Medicine and Biology Workshop · doi:10.1109/embsw.2007.4454171 · Cited by 29
“Similarly, monitoring of brain function can be provided by probes implanted within the brain [7] that communicate via an NFC transponder embedded within the skull.”
Background
Metadata
- Authors
- McCreery, D., Lossinsky, A., Pikov, V., & Liu, X.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-04
- Volume
- 53
- Issue
- 4
- Pages
- 726-737
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2149638288
- Cited by
- 76
- References
- 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.