Improving EMG-Based Muscle Force Estimation by Using a High-Density EMG Grid and Principal Component Analysis
Open accessAbstract
The accuracy of predictions of muscle force based on electromyography (EMG) is an important issue in biomechanics and kinesiology. Since human skeletal muscles show a high diversity and heterogeneity in their fiber architecture, it is difficult to properly align electrodes to the muscle fiber direction. Against this background, we analyzed the effect of different bipolar configuration directions on EMG-based force estimation. In addition, we investigated whether principal component analysis (PCA) can improve this estimation. High-density surface-EMG from the triceps brachii muscle and the extension force of the elbow were measured in 11 subjects. The root mean square difference (RMSD) between predicted and measured force was determined. We found the best bipolar configuration direction to cause a 13% lower RMSD relative to the worst direction. Optimal results were obtained with electrodes aligned with the expected main muscle fiber direction. We found that PCA reduced RMSD by about 40% compared to conventional bipolar electrodes and by about 12% compared to optimally aligned multiple bipolar electrodes. Thus, PCA contributes to the accuracy of EMG-based estimation of muscle force when using a high-density EMG grid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326653 · Cited by 126
Cited by
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Methodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
Self-citationClinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
Self-citation
Metadata
- Authors
- Staudenmann, D., Kingma, I., Daffertshofer, A., Stegeman, D. F., & vanDieen, J. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-04
- Volume
- 53
- Issue
- 4
- Pages
- 712-719
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2119391976
- Cited by
- 172
- References
- 1
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.