CoChat

Quantifying Cortical Activity During General Anesthesia Using Wavelet Analysis

Zikov, T., Bibian, S., Dumont, G.A., Huzmezan, M., Ries, C.R. · 2006 · IEEE Transactions on Biomedical Engineering
Cited by 177

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

This paper reports on a novel method for quantifying the cortical activity of a patient during general anesthesia as a surrogate measure of the patient's level of consciousness. The proposed technique is based on the analysis of a single-channel (frontal) electroencephalogram (EEG) signal using stationary wavelet transform (SWT). The wavelet coefficients calculated from the EEG are pooled into a statistical representation, which is then compared to two well-defined states: the awake state with normal EEG activity, and the isoelectric state with maximal cortical depression. The resulting index, referred to as the wavelet-based anesthetic value for central nervous system monitoring (WAV(CNS)), quantifies the depth of consciousness between these two extremes. To validate the proposed technique, we present a clinical study which explores the advantages of the WAV(CNS) in comparison with the BIS monitor (Aspect Medical Systems, MA), currently a reference in consciousness monitoring. Results show that the WAV(CNS) and BIS are well correlated (r = 0.969) during periods of steady-state despite fundamental algorithmic differences. However, in terms of dynamic behavior, the WAV(CNS) offers faster tracking of transitory changes at induction and emergence, with an average lead of 15-30 s. Furthermore, and conversely to the BIS, the WAV(CNS) regains its preinduction baseline value when patients are responding to verbal command after emergence from anesthesia. We conclude that the proposed analysis technique is an attractive alternative to BIS monitoring. In addition, we show that the WAV(CNS) dynamics can be modeled as a linear time invariant transfer function. This index is, therefore, well suited for use as a feedback sensor in advisory systems, closed-loop control schemes, and for the identification of the pharmacodynamic models of anesthetic drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2006.870255

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

Metadata

Authors
Zikov, T., Bibian, S., Dumont, G. A., Huzmezan, M., & Ries, C. R.
Venue
IEEE Transactions on Biomedical Engineering
Published
2006-04
Volume
53
Issue
4
Pages
617-632
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2162067857
Cited by
177
References
23
FWCI
7.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.