Quantifying Cortical Activity During General Anesthesia Using Wavelet Analysis
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
This paper reports on a novel method for quantifying the cortical activity of a patient during general anesthesia as a surrogate measure of the patient's level of consciousness. The proposed technique is based on the analysis of a single-channel (frontal) electroencephalogram (EEG) signal using stationary wavelet transform (SWT). The wavelet coefficients calculated from the EEG are pooled into a statistical representation, which is then compared to two well-defined states: the awake state with normal EEG activity, and the isoelectric state with maximal cortical depression. The resulting index, referred to as the wavelet-based anesthetic value for central nervous system monitoring (WAV(CNS)), quantifies the depth of consciousness between these two extremes. To validate the proposed technique, we present a clinical study which explores the advantages of the WAV(CNS) in comparison with the BIS monitor (Aspect Medical Systems, MA), currently a reference in consciousness monitoring. Results show that the WAV(CNS) and BIS are well correlated (r = 0.969) during periods of steady-state despite fundamental algorithmic differences. However, in terms of dynamic behavior, the WAV(CNS) offers faster tracking of transitory changes at induction and emergence, with an average lead of 15-30 s. Furthermore, and conversely to the BIS, the WAV(CNS) regains its preinduction baseline value when patients are responding to verbal command after emergence from anesthesia. We conclude that the proposed analysis technique is an attractive alternative to BIS monitoring. In addition, we show that the WAV(CNS) dynamics can be modeled as a linear time invariant transfer function. This index is, therefore, well suited for use as a feedback sensor in advisory systems, closed-loop control schemes, and for the identification of the pharmacodynamic models of anesthetic drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914 · cited 1×
“the true cortical EEG) after thresholding in the wavelet domain [35], [36].”
BackgroundOn optimal and data-based histograms
SCOTT, D. W. (1979) · Biometrika · doi:10.1093/biomet/66.3.605 · Cited by 1,819 · cited 1×
“It has been shown [37] that the optimal histogram bin size, which provides the most efficient, unbiased estimation of the PDF, is achieved when”
BackgroundA Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503 · cited 2×
“, a specific range of anesthetic effect where they perform best) [14].”
BackgroundMyles, P., Leslie, K., McNeil, J., Forbes, A., & Chan, M. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16300-9 · Cited by 1,301
The Stationary Wavelet Transform and some Statistical Applications
Nason, G. P., & Silverman, B. W. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_17 · Cited by 1,122 · cited 1×
“the true cortical EEG) after thresholding in the wavelet domain [35], [36].”
BackgroundAnesthetic Management and One-Year Mortality After Noncardiac Surgery
Monk, T. G., Saini, V., Weldon, B. C., & Sigl, J. C. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000147519.82841.5e · Cited by 890 · cited 1×
“tween BIS values during anesthesia maintenance and long-term postoperative mortality rates in older noncardiac patients [6], [7].”
BackgroundDescription of the Entropy™ algorithm as applied in the Datex‐Ohmeda S/5™ Entropy Module
Viertiö‐Oja, H., Maja, V., Särkelä, M., Talja, P., Tenkanen, N., Tolvanen‐Laakso, H., Paloheimo, M., Vakkuri, A., Yli‐Hankala, A., & Meriläinen, P. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.00322.x · Cited by 582 · cited 1×
“monitor based on entropy analysis of the EEG [22], [23].”
MethodRosow, C. E., & Manberg, P. J. (2001) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(01)80018-3 · Cited by 357
Vakkuri, A., Yli‐Hankala, A., Talja, P., Mustola, S., Tolvanen‐Laakso, H., Sampson, T., & Viertiö‐Oja, H. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.00323.x · Cited by 293 · cited 1×
“monitor based on entropy analysis of the EEG [22], [23].”
MethodHans, P., Dewandre, P.-Y., Brichant, J. F., & Bonhomme, V. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei047 · Cited by 271 · cited 1×
“First reports seem to indicate that this technology provides useful information about the patient anesthetic state, similarly to the BIS [24]–[27].”
ResultA field theory of consciousness.
John, E. R. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0508 · Cited by 214 · cited 3×
“[1] that loss of consciousness after anesthetic administration showed a marked drop in the -band activity, along with an increase in slower waveforms, which is in line with our findings.”
BackgroundResultInfluentialAbsalom, A. R., Sutcliffe, N., & Kenny, G. N. (2002) · Anesthesiology · doi:10.1097/00000542-200201000-00017 · Cited by 212
SLEIGH, J. W., & Donovan, J. K. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.5.666 · Cited by 152
Practical Issues in Bispectral Analysis of Electroencephalographic Signals
Hagihira, S., Takashina, M., Mori, T., Mashimo, T., & Yoshiya, I. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200110000-00032 · Cited by 144 · cited 2×
“, when the patient’s state of consciousness remains constant, since transitory states are affected by the time delay induced by the bispectral analysis [13].”
BackgroundA wavelet based de-noising technique for ocular artifact correction of the electroencephalogram
Zikov, T., Bibian, S., Dumont, G. A., Huzmezan, M., & Ries, C. R. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1134407 · Cited by 136
Self-citationSchmidt, G. N., Bischoff, P., Standl, T., Hellstern, A., Teuber, O., & Esch, J. S. A. (2004) · Anesthesiology · doi:10.1097/00000542-200412000-00007 · Cited by 127 · cited 1×
“First reports seem to indicate that this technology provides useful information about the patient anesthetic state, similarly to the BIS [24]–[27].”
ResultModeling and closed-loop control of hypnosis by means of bispectral index (BIS) with isoflurane
Gentilini, A., Rossoni-Gerosa, M., Frei, C. W., Wymann, R., Morari, M., Zbinden, A. M., & Schnider, T. W. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936364 · Cited by 124 · cited 1×
“While the BIS has been used in closed loop [8]–[10], it has been reported that the accuracy of dose-response models based on the BIS is mediocre [11], [12].”
MethodDifferent benefit of bispectal index (BIS™) in desflurane and propofol anesthesia
Luginbühl, M., Wüthrich, S., Petersen‐Felix, S., Zbinden, A. M., & Schnider, T. W. (2003) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2003.00041.x · Cited by 96
Muncaster, A. R. G., Sleigh, J. W., & Williams, A. M. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000040143.95962.36 · Cited by 76 · cited 1×
“Finally, it is a well-known fact that the BIS does not regain its baseline value after emergence [12], [15], and that low EEG amplitudes can yield paradoxical results [16], [17].”
BackgroundSchmidt, G. N., Bischoff, P., Standl, T., Jensen, K., Voigt, M., & Esch, J. S. A. (2003) · Anesthesiology · doi:10.1097/00000542-200311000-00012 · Cited by 61 · cited 2×
“As compared to the BIS, the Narcotrend seems to perform better during emergence as it regains its baseline value upon discontinuation of the drug effect [21].”
BackgroundResultEntropy is blind to nitrous oxide. Can we see why?
Sleigh, J. W., & Barnard, J. P. M. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh039 · Cited by 33 · cited 6×
“Each individual time course is synchronized using the LOC event.”
BackgroundInfluentialEEG-based indices of anaesthesia: correlation between bispectral index and patient state index?
Schneider, G. H., Mappes, A., Neißendorfer, T., Schabacker, M., Kuppe, H., & Kochs, E. F. (2004) · European Journal of Anaesthesiology · doi:10.1097/00003643-200401000-00002 · Cited by 31 · cited 1×
“[19] pointed out the relative lack of correlation between the two indexes in surgical patients .”
BackgroundSpectral entropy—what has it to do with anaesthesia, and the EEG?
Jäntti, V., & Alahuhta, S. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh578 · Cited by 30 · cited 1×
“One of the most significant accomplishments of such technologies is that they have created a shift in the anesthesiologist’s interest from spinal cord reflexes to the cortex [ 28 ], which is a target site of anesthetics, even though hemodynamics, respiration and blood oxygenation remain the primary endpoints used to e…”
Background
Cited by
Robust control of depth of anesthesia
Dumont, G. A., Martinez, A., & Ansermino, J. M. (2009) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.1087 · Cited by 161
Self-citation
Metadata
- Authors
- Zikov, T., Bibian, S., Dumont, G. A., Huzmezan, M., & Ries, C. R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-04
- Volume
- 53
- Issue
- 4
- Pages
- 617-632
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2162067857
- Cited by
- 177
- References
- 23
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.