Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The purpose of the present theoretical study was to examine the spatial resolution of electroencephalography (EEG) by means of the accuracy of the inverse cortical EEG solution. The study focused on effect of the amount of measurement noise and the number of electrodes on the spatial resolution with different resistivity ratios for the scalp, skull and brain. The results show that if the relative skull resistivity is lower than earlier believed, the spatial resolution of different electrode systems is less sensitive to the measurement noise. Furthermore, there is then also greater advantage to be obtained with high-resolution EEG at realistic noise levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Self-citationEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Cited by
EEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900
“The latter form the material core of cognitive functions.”
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
EEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
The Role of Sleep in Directed Forgetting and Remembering of Human Memories
Saletin, J. M., Goldstein, A. N., & Walker, M. P. (2011) · Cerebral Cortex · doi:10.1093/cercor/bhr034 · Cited by 151
Metadata
- Authors
- Ryynanen, O. R. M., Hyttinen, J. A. K., & Malmivuo, J. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-09
- Volume
- 53
- Issue
- 9
- Pages
- 1851-1858
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2123114114
- Cited by
- 68
- References
- 2
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull. https://app.cochat.ai/papers/10.1109/tbme.2006.873744
- The paper
- Ryynanen, O. R. M., Hyttinen, J. A. K., & Malmivuo, J. A. (2006). Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.873744
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.