The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Modified Beamformers for Coherent Source Region Suppression
Open accessAbstract
Many tomographic source localization algorithms used in biomagnetic imaging assume, explicitly or sometimes implicitly, that the source activity at different brain locations are either independent or that the correlation structure between sources is known. Among these algorithms is a class of adaptive spatial filters known as beamformers, which have superior spatiotemporal resolution abilities. The performance of beamformers is robust to weakly coherent sources. However, these algorithms are extremely sensitive to the presence of strongly coherent sources. A frequent mode of failure in beamformers occurs with reconstruction of auditory evoked fields (AEFs), in which bilateral auditory cortices are highly coherent in their activation. Here, we present a novel beamformer that suppresses activation from regions with interfering coherent sources. First, a volume containing the interfering sources is defined. The lead field matrix for this volume is computed and reduced into a few significant columns using singular value decomposition (SVD). A vector beamformer is then constructed by rejecting the contribution of sources in the suppression region while allowing for source reconstruction at other specified regions. Performance of this algorithm was first validated with simulated data. Subsequent tests of this modified beamformer were performed on bilateral AEF data. An unmodified vector beamformer using whole head coverage misplaces the source medially. After defining a suppression region containing the temporal cortex on one side, the described method consistently results in clear focal activations at expected regions of the contralateral superior temporal plane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 1×
“In contrast to other techniques, MEG provides a direct measure of the brain’s neuronal activity that is relatively undistorted by the various tissue layers of the head [2].”
ResultMedial prefrontal cortex generates frontal midline theta rhythm
Ishii, R., Shinosaki, K., Ukai, S., Inouye, T., Ishihara, T., Yoshimine, T., Hirabuki, N., Asada, H., Kihara, T., Robinson, S. E., et al. (1999) · NeuroReport · doi:10.1097/00001756-199903170-00003 · Cited by 494
Cited by
Measuring functional connectivity using MEG: methodology and comparison with fcMRI
Brookes, M. J., Hale, J. R., Zumer, J. M., Stevenson, C. M., Francis, S. T., Barnes, G. R., Owen, J. P., Morris, P. G., & Nagarajan, S. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.054 · Cited by 519
Self-citationHillebrand, A., Barnes, G. R., Bosboom, J. L., Berendse, H. W., & Stam, C. J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.005 · Cited by 416
How reliable are MEG resting-state connectivity metrics?
Colclough, G. L., Woolrich, M. W., Tewarie, P. K., Brookes, M. J., Quinn, A. J., & Smith, S. M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.05.070 · Cited by 414
Adverse Listening Conditions and Memory Load Drive a Common Alpha Oscillatory Network
Obleser, J., Wöstmann, M., Hellbernd, N., Wilsch, A., & Maess, B. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.4908-11.2012 · Cited by 224
“Beamformer methods are known to encounter difficulties in resolving correlated sources, for example, from simultaneously active bilateral auditory cortex (Dalal et al., 2006).”
BackgroundThe saccadic spike artifact in MEG
Carl, C., Açık, A., König, P., Engel, A. K., & Hipp, J. F. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.020 · Cited by 110
Metadata
- Authors
- Dalal, S. S., Sekihara, K., & Nagarajan, S. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-07
- Volume
- 53
- Issue
- 7
- Pages
- 1357-1363
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2152484798
- Cited by
- 158
- References
- 4
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.