The DOI matches its Crossref record.
Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm
Abstract
Exoskeleton robots are promising assistive/rehabilitative devices that can help people with force deficits or allow the recovery of patients who have suffered from pathologies such as stroke. The key component that allows the user to control the exoskeleton is the human machine interface (HMI). Setting the HMI at the neuro-muscular level may lead to seamless integration and intuitive control of the exoskeleton arm as a natural extension of the human body. At the core of the exoskeleton HMI there is a model of the human muscle, the "myoprocessor," running in real-time and in parallel to the physiological muscle, that predicts joint torques as a function of the joint kinematics and neural activation levels. This paper presents the development of myoprocessors for the upper limb based on the Hill phenomenological muscle model. Genetic algorithms are used to optimize the internal parameters of the myoprocessors utilizing an experimental database that provides inputs to the model and allows for performance assessment. The results indicate high correlation between joint moment predictions of the model and the measured data. Consequently, the myoprocessor seems an adequate model, sufficiently robust for further integration into the exoskeleton control system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Human–Robot Synchrony: Flexible Assistance Using Adaptive Oscillators
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Carrozza, M. C., & Ijspeert, A. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089629 · Cited by 158
Sartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148
Metadata
- Authors
- Cavallaro, E. E., Rosen, J., Perry, J. C., & Burns, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-11
- Volume
- 53
- Issue
- 11
- Pages
- 2387-2396
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2146117110
- Cited by
- 230
- References
- 0
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm. https://app.cochat.ai/papers/10.1109/tbme.2006.880883
- The paper
- Cavallaro, E. E., Rosen, J., Perry, J. C., & Burns, S. (2006). Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.880883
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.