CoChat

A Novel Dry Active Electrode for EEG Recording

Fonseca, C., Cunha, J. P. Silva, Martins, R. E., Ferreira, V. M., de Sa, J. P. Marques, Barbosa, M. A., Martins da Silva, A. · 2007 · IEEE Transactions on Biomedical Engineering
Cited by 151

The DOI matches its Crossref record.

Abstract

The design and testing of a "dry" active electrode for electroencephalographic recording is described. A comparative study between the EEG signals recorded in human volunteers simultaneously with the classical Ag-AgCl and "dry" active electrodes was carried out and the reported preliminary results are consistent with a better performance of these devices over the conventional Ag-AgCl electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2006.884649

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 151

Metadata

Authors
Fonseca, C., Cunha, J. P. S., Martins, R. E., Ferreira, V. M., de Sa, J. P. M., Barbosa, M. A., & Martins da Silva, A.
Venue
IEEE Transactions on Biomedical Engineering
Published
2007-01
Volume
54
Issue
1
Pages
162-165
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1999803854
Cited by
151
References
0
FWCI
1.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Dry Active Electrode for EEG Recording. https://app.cochat.ai/papers/10.1109/tbme.2006.884649
The paper
Fonseca, C., Cunha, J. P. S., Martins, R. E., Ferreira, V. M., de Sa, J. P. M., Barbosa, M. A., & Martins da Silva, A. (2007). A Novel Dry Active Electrode for EEG Recording. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.884649

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.