The DOI matches its Crossref record.
Cerebrospinal Fluid Flow in the Normal and Hydrocephalic Human Brain
Abstract
Advances in magnetic resonance (MR) imaging techniques enable the accurate measurements of cerebrospinal fluid (CSF) flow in the human brain. In addition, image reconstruction tools facilitate the collection of patient-specific brain geometry data such as the exact dimensions of the ventricular and subarachnoidal spaces (SAS) as well as the computer-aided reconstruction of the CSF-filled spaces. The solution of the conservation of CSF mass and momentum balances over a finite computational mesh obtained from the MR images predict the patients' CSF flow and pressure field. Advanced image reconstruction tools used in conjunction with first principles of fluid mechanics allow an accurate verification of the CSF flow patters for individual patients. This paper presents a detailed analysis of pulsatile CSF flow and pressure dynamics in a normal and hydrocephalic patient. Experimental CSF flow measurements and computational results of flow and pressure fields in the ventricular system, the SAS and brain parenchyma are presented. The pulsating CSF motion is explored in normal and pathological conditions of communicating hydrocephalus. This paper predicts small transmantle pressure differences between lateral ventricles and SASs (approximately 10 Pa). The transmantle pressure between ventricles and SAS remains small even in the hydrocephalic patient (approximately 30 Pa), but the ICP pulsatility increases by a factor of four. The computational fluid dynamics (CFD) results of the predicted CSF flow velocities are in good agreement with Cine MRI measurements. Differences between the predicted and observed CSF flow velocities in the prepontine area point towards complex brain-CSF interactions. The paper presents the complete computational model to predict the pulsatile CSF flow in the cranial cavity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Striepens, N., Kendrick, K. M., Hanking, V., Landgraf, R., Wüllner, U., Maier, W., & Hurlemann, R. (2013) · Scientific Reports · doi:10.1038/srep03440 · Cited by 452
Understanding wiring and volume transmission
Agnati, L. F., Guidolin, D., Guescini, M., Genedani, S., & Fuxe, K. (2010) · Brain Research Reviews · doi:10.1016/j.brainresrev.2010.03.003 · Cited by 287
The electrical conductivity of human cerebrospinal fluid in vivo
Latikka, J., & Eskola, H. (2019) · IFMBE Proceedings · doi:10.1007/978-981-10-9035-6_142 · Cited by 15
Metadata
- Authors
- Linninger, A. A., Xenos, M., Zhu, D. C., Somayaji, M. R., Kondapalli, S., & Penn, R. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-02
- Volume
- 54
- Issue
- 2
- Pages
- 291-302
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2122570678
- Cited by
- 182
- References
- 0
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebrospinal Fluid Flow in the Normal and Hydrocephalic Human Brain. https://app.cochat.ai/papers/10.1109/tbme.2006.886853
- The paper
- Linninger, A. A., Xenos, M., Zhu, D. C., Somayaji, M. R., Kondapalli, S., & Penn, R. D. (2007). Cerebrospinal Fluid Flow in the Normal and Hydrocephalic Human Brain. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.886853
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.