Ambulatory Assessment of Ankle and Foot Dynamics
Open accessAbstract
Ground reaction force (GRF) measurement is important in the analysis of human body movements. The main drawback of the existing measurement systems is the restriction to a laboratory environment. This paper proposes an ambulatory system for assessing the dynamics of ankle and foot, which integrates the measurement of the GRF with the measurement of human body movement. The GRF and the center of pressure (CoP) are measured using two six-degrees-of-freedom force sensors mounted beneath the shoe. The movement of foot and lower leg is measured using three miniature inertial sensors, two rigidly attached to the shoe and one on the lower leg. The proposed system is validated using a force plate and an optical position measurement system as a reference. The results show good correspondence between both measurement systems, except for the ankle power estimation. The root mean square (RMS) difference of the magnitude of the GRF over 10 evaluated trials was (0.012 +/- 0.001) N/N (mean +/- standard deviation), being (1.1 +/- 0.1)% of the maximal GRF magnitude. It should be noted that the forces, moments, and powers are normalized with respect to body weight. The CoP estimation using both methods shows good correspondence, as indicated by the RMS difference of (5.1 +/- 0.7) mm, corresponding to (1.7 +/- 0.3)% of the length of the shoe. The RMS difference between the magnitudes of the heel position estimates was calculated as (18 +/- 6) mm, being (1.4 +/- 0.5)% of the maximal magnitude. The ankle moment RMS difference was (0.004 +/- 0.001) Nm/N, being (2.3 +/- 0.5)% of the maximal magnitude. Finally, the RMS difference of the estimated power at the ankle was (0.02 +/- 0.005) W/N, being (14 +/- 5)% of the maximal power. This power difference is caused by an inaccurate estimation of the angular velocities using the optical reference measurement system, which is due to considering the foot as a single segment. The ambulatory system considers separate heel and forefoot segments, thus allowing an additional foot moment and power to be estimated. Based on the results of this research, it is concluded that the combination of the instrumented shoe and inertial sensing is a promising tool for the assessment of the dynamics of foot and ankle in an ambulatory setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Self-citation
Cited by
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Bartolozzi, C., Natale, L., Nori, F., & Metta, G. (2016) · Nature Materials · doi:10.1038/nmat4731 · Cited by 308
Joint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 262
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Rouhani, H., Favre, J., Crevoisier, X., & Aminian, K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006674 · Cited by 72
Metadata
- Authors
- Schepers, H. M., Koopman, H. F. J. M., & Veltink, P. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-05
- Volume
- 54
- Issue
- 5
- Pages
- 895-902
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2102895608
- Cited by
- 186
- References
- 1
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.