Abstract
In this paper, a new approach aimed at improving the performance of intraneural longitudinal interfaces (tf-LIFEs) with the peripheral nervous system (PNS) is presented. Our goal is to develop a movable interface by embedding microactuators into the flexible tf-LIFEs structure. In this way, the optimal position of the electrical contacts can be searched inside the PNS and lost connections with neural cells could be replaced. For this purpose a thin film of shape memory alloy (tf-SMA) was selected. A multisegmented SMA was realized and embedded between two polyimide thin films in order to simulate the tf-LIFE structure. Thermal evaluation, fabrication procedure, the first characterization and preliminary experimental results of the new movable interface are described in the manuscript. A total controllable stroke of about 10 microm was obtained for the presented prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 5×
“I N the recent past new advancements have been achieved in the field of flexible implantable neural interfaces with the peripheral nervous systems (PNS) [1], and more attention has been recently devoted to the problem of their chronic usability.”
BackgroundInfluentialSelf-citationLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Self-citation
Cited by
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Self-citationImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Self-citationInterfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Metadata
- Authors
- Bossi, S., Menciassi, A., Koch, K. P., Hoffmann, K.-P., Yoshida, K., Dario, P., & Micera, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-06
- Volume
- 54
- Issue
- 6
- Pages
- 1115-1120
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2148796539
- Cited by
- 29
- References
- 2
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›