The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Predicting Arterial Stiffness From the Digital Volume Pulse Waveform
Abstract
Cardiovascular disease (CVD) is currently the biggest single cause of mortality in the developed world, hence, the early detection of its onset is vital for effective prevention therapies. Aortic stiffness as measured by aortic pulse wave velocity (PWV) has been shown to be an independent predictor of CVD, however, the measurement of PWV is complex and time consuming. Recent studies have shown that pulse contour characteristics depend on arterial properties such as arterial stiffness. This paper presents a method for estimating PWV from the digital volume pulse (DVP), a waveform that can be rapidly and simply acquired by measuring the transmission of infra-red light through the finger pulp. PWV and DVP were measured on 461 subjects attending a clinic in South East London. Techniques for extracting features from the DVP contour based on physiology and information theory were compared. Low and high stiffness were defined according to a threshold level of PWV chosen to be 10 m/s. Using a support vector machine-based classifier, it is possible to achieve high overall classification rates on unseen data. Further, the use of support vector regression techniques lead to a direct real-valued estimate of PWV which outperforms previous methods based on multilinear regression. We, therefore, conclude that support vector machine-based classification and regression techniques provide effective prediction of arterial stiffness from the simple measurement of the digital volume pulse. This technique could be usefully employed as a cheap and effective CVD screening technique for use in general practice clinics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493
Grundy, S. M., Pasternak, R., Greenland, P., Smith, S., & Fuster, V. (1999) · Circulation · doi:10.1161/01.cir.100.13.1481 · Cited by 1,315
Cited by
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Metadata
- Authors
- Alty, S. R., Angarita-Jaimes, N., Millasseau, S. C., & Chowienczyk, P. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-12
- Volume
- 54
- Issue
- 12
- Pages
- 2268-2275
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2101342650
- Cited by
- 190
- References
- 2
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.