Sleep Versus Wake Classification From Heart Rate Variability Using Computational Intelligence: Consideration of Rejection in Classification Models
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Reliability of classification performance is important for many biomedical applications. A classification model which considers reliability in the development of the model such that unreliable segments are rejected would be useful, particularly, in large biomedical data sets. This approach is demonstrated in the development of a technique to reliably determine sleep and wake using only the electrocardiogram (ECG) of infants. Typically, sleep state scoring is a time consuming task in which sleep states are manually derived from many physiological signals. The method was tested with simultaneous 8-h ECG and polysomnogram (PSG) determined sleep scores from 190 infants enrolled in the collaborative home infant monitoring evaluation (CHIME) study. Learning vector quantization (LVQ) neural network, multilayer perceptron (MLP) neural network, and support vector machines (SVMs) are tested as the classifiers. After systematic rejection of difficult to classify segments, the models can achieve 85%-87% correct classification while rejecting only 30% of the data. This corresponds to a Kappa statistic of 0.65-0.68. With rejection, accuracy improves by about 8% over a model without rejection. Additionally, the impact of the PSG scored indeterminate state epochs is analyzed. The advantages of a reliable sleep/wake classifier based only on ECG include high accuracy, simplicity of use, and low intrusiveness. Reliability of the classification can be built directly in the model, such that unreliable segments are rejected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polysomnographic pattern recognition for automated classification of sleep-waking states in infants
Estévez, P. A., Held, C. M., Holzmann, C. A., Perez, C. A., Pérez, J. P., Heiss, J., Garrido, M., & Peirano, P. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347703 · Cited by 69
Cited by
Review and classification of variability analysis techniques with clinical applications
Bravi, A., Longtin, A., & Seely, A. J. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-90 · Cited by 265
Machine learning with a reject option: A survey
Hendrickx, K., Perini, L., Van der Plas, D., Meert, W., & Davis, J. (2024) · Machine Learning · doi:10.1007/s10994-024-06534-x · Cited by 134
Clinical applications of artificial intelligence in sleep medicine: A sleep clinician’s perspective
Bandyopadhyay, A., & Goldstein, C. (2023) · Sleep And Breathing · doi:10.1007/s11325-022-02592-4 · Cited by 108
“While most studies utilize electroencephalogram (EEG) signal for sleep staging, several studies have combined EEG channels with electromyogram (EMG) and electro-oculo-gram (EOG channels) [32].”
BackgroundKelwade, J. P., & Salankar, S. S. (2016) · 2016 IEEE First International Conference on Control, Measurement and Instrumentation (CMI) · doi:10.1109/cmi.2016.7413789 · Cited by 36
Sano, A., & Picard, R. W. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6943744 · Cited by 25
“Some other researchers have applied machine learning or new algorithms to improve the accuracy [3][4][5] or used other data (heart rate variability from electrocardiogram (ECG)) [6][7].”
Metadata
- Authors
- Lewicke, A., Sazonov, E., Corwin, M. J., Neuman, M., & Schuckers, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-01
- Volume
- 55
- Issue
- 1
- Pages
- 108-118
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2145675843
- Cited by
- 74
- References
- 1
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.