The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Principal Component Analysis-Enhanced Cosine Radial Basis Function Neural Network for Robust Epilepsy and Seizure Detection
Abstract
A novel principal component analysis (PCA)-enhanced cosine radial basis function neural network classifier is presented. The two-stage classifier is integrated with the mixed-band wavelet-chaos methodology, developed earlier by the authors, for accurate and robust classification of electroencephalogram (EEGs) into healthy, ictal, and interictal EEGs. A nine-parameter mixed-band feature space discovered in previous research for effective EEG representation is used as input to the two-stage classifier. In the first stage, PCA is employed for feature enhancement. The rearrangement of the input space along the principal components of the data improves the classification accuracy of the cosine radial basis function neural network (RBFNN) employed in the second stage significantly. The classification accuracy and robustness of the classifier are validated by extensive parametric and sensitivity analysis. The new wavelet-chaos-neural network methodology yields high EEG classification accuracy (96.6%) and is quite robust to changes in training data with a low standard deviation of 1.4%. For epilepsy diagnosis, when only normal and interictal EEGs are considered, the classification accuracy of the proposed model is 99.3%. This statistic is especially remarkable because even the most highly trained neurologists do not appear to be able to detect interictal EEGs more than 80% of the times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Analysis of EEG records in an epileptic patient using wavelet transform
Adeli, H., Zhou, Z., & Dadmehr, N. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00340-0 · Cited by 1,154
Self-citationA Wavelet-Chaos Methodology for Analysis of EEGs and EEG Subbands to Detect Seizure and Epilepsy
Adeli, H., Ghosh-Dastidar, S., & Dadmehr, N. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886855 · Cited by 686
Self-citationRecurrent neural networks employing Lyapunov exponents for EEG signals classification
GULER, N., UBEYLI, E., & GULER, I. (2005) · Expert Systems with Applications · doi:10.1016/j.eswa.2005.04.011 · Cited by 503
Mixed-Band Wavelet-Chaos-Neural Network Methodology for Epilepsy and Epileptic Seizure Detection
Ghosh-Dastidar, S., Adeli, H., & Dadmehr, N. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891945 · Cited by 470
Self-citationEpileptic seizure prediction and control
Iasemidis, L. D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.810705 · Cited by 363
Recurrent neural network based prediction of epileptic seizures in intra- and extracranial EEG
Petrosian, A., Prokhorov, D., Homan, R., Dasheiff, R., & Wunsch, D. (2000) · Neurocomputing · doi:10.1016/s0925-2312(99)00126-5 · Cited by 269
Seizure prediction by non‐linear time series analysis of brain electrical activity
Elger, C. E., & Lehnertz, K. (1998) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1998.00090.x · Cited by 263
Automatic Detection of Seizures and Spikes
Gotman, J. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199903000-00005 · Cited by 232
Fuzzy-Wavelet RBFNN Model for Freeway Incident Detection
Adeli, H., & Karim, A. (2000) · Journal of Transportation Engineering · doi:10.1061/(asce)0733-947x(2000)126:6(464 · Cited by 224
Self-citationIndependent component analysis for EEG source localization
Евгеньевич, Ж. Л., Weinstein, D. M., & Johnson, C. R. (2000) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.844386 · Cited by 136
PCA+HMM+SVM for EEG pattern classification
Lee, H., & Choi, S. (2003) · International Symposium on Signal Processing and Its Applications (ISSPA) · doi:10.1109/isspa.2003.1224760 · Cited by 115
Time dependencies in the occurrences of epileptic seizures
Iasemidis, L. D., Olson, L. D., Savit, R. S., & Sackellares, J. C. (1994) · Epilepsy Research · doi:10.1016/0920-1211(94)90081-7 · Cited by 104
Dynamics of local neuronal networks: control parameters and state bifurcations in epileptogenesis
Lopes, F. H. D. S., Pijn, J. P. M., & Wadman, W. J. (1994) · Progress in brain research · doi:10.1016/s0079-6123(08)60552-x · Cited by 79
Cited by
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., & Adeli, H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.09.017 · Cited by 1,647
Self-citationAI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713
Automated EEG-based screening of depression using deep convolutional neural network
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., Adeli, H., & Subha, D. P. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.012 · Cited by 650
Self-citationAn electroencephalographic signature predicts antidepressant response in major depression
Wu, W., Zhang, Y., Jiang, J., Lucas, M. V., Fonzo, G. A., Rolle, C. E., Cooper, C., Chin-Fatt, C., Krepel, N., Cornelssen, C. A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0397-3 · Cited by 302
Artificial Intelligence Techniques for Automated Diagnosis of Neurological Disorders
Raghavendra, U., Acharya, U. R., & Adeli, H. (2019) · European Neurology · doi:10.1159/000504292 · Cited by 174
Self-citation
Metadata
- Authors
- Ghosh-Dastidar, S., Adeli, H., & Dadmehr, N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-02
- Volume
- 55
- Issue
- 2
- Pages
- 512-518
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2122923860
- Cited by
- 466
- References
- 14
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.