The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Analysis of First-Derivative Based QRS Detection Algorithms
Open accessAbstract
Accurate QRS detection is an important first step for the analysis of heart rate variability. Algorithms based on the differentiated ECG are computationally efficient and hence ideal for real-time analysis of large datasets. Here, we analyze traditional first-derivative based squaring function (Hamilton-Tompkins) and Hilbert transform-based methods for QRS detection and their modifications with improved detection thresholds. On a standard ECG dataset, the Hamilton-Tompkins algorithm had the highest detection accuracy (99.68% sensitivity, 99.63% positive predictivity) but also the largest time error. The modified Hamilton-Tompkins algorithm as well as the Hilbert transform-based algorithms had comparable, though slightly lower, accuracy; yet these automated algorithms present an advantage for real-time applications by avoiding human intervention in threshold determination. The high accuracy of the Hilbert transform-based method compared to detection with the second derivative of the ECG is ascribable to its inherently uniform magnitude spectrum. For all algorithms, detection errors occurred mainly in beats with decreased signal slope, such as wide arrhythmic beats or attenuated beats. For best performance, a combination of the squaring function and Hilbert transform-based algorithms can be applied such that differences in detection will point to abnormalities in the signal that can be further analyzed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
The principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
Autonomic activity during human sleep as a function of time and sleep stage
Trinder, J., Kleiman, J., Carrington, M., Smith, S., Breen, S., Tan, N., & Kim, Y. (2001) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2001.00263.x · Cited by 507
The use of the Hilbert transform in ECG signal analysis
Benitez, D., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P. (2001) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00009-9 · Cited by 489
Cited by
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
A novel method for detecting R-peaks in electrocardiogram (ECG) signal
Manikandan, M. S., & Soman, K. P. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.03.004 · Cited by 393
Role of editing of R–R intervals in the analysis of heart rate variability
Peltola, M. A. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00148 · Cited by 300
QRS detection based on wavelet coefficients
Zidelmal, Z., Amirou, A., Adnane, M., & Belouchrani, A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.12.004 · Cited by 283
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Sahoo, S., Kanungo, B., Behera, S., & Sabut, S. (2017) · Measurement · doi:10.1016/j.measurement.2017.05.022 · Cited by 254
Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe
Dehghanojamahalleh, S., & Kaya, M. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2938506 · Cited by 25
Metadata
- Authors
- Arzeno, N. M., Deng, Z.-D., & Poon, C.-S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-02
- Volume
- 55
- Issue
- 2
- Pages
- 478-484
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2136293280
- Cited by
- 413
- References
- 25
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.