Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe
Open accessAbstract
Sex plays an important role in the normal cardiovascular system function including resting heart rate and arterial blood pressure. In addition, it has been reported that men and women are at different levels of risk for cardiovascular diseases. The aim of this study was to evaluate and compare the temporal and morphological features of both finger and toe photoplethysmography (PPG), and anthropometric and biological parameters with respect to sex. A customized PPG and electrocardiography (ECG) combo device was developed to measure the signals of interest. ECG/PPG features in addition to subjects' information were compared regarding finger and toe PPGs. Eighty-eight subjects participated in the study. Linear regression and Student's t-test were used for statistical analysis. Our results revealed that pulse arrival time (PAT), pulse transit time (PTT), systolic pulse transit time (SPTT), and the ratio of areas under the PPG waveform from the onset to the inflection point and the inflection point to the end of the waveform (S2/S1), are dependent on sex. The highest dependence was shown for the finger PTT while the toe PTT did not indicate any significant dependence on sex. This is the first study that evaluates the effect of sex on cardiovascular system function using finger and toe PPG based features which can help to understand sex-based risk factors for cardiovascular diseases and to improve related disease management and treatments.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dehghanojamahalleh et al. demonstrated variations in PPG morphology attributed to gender differences, with direct influence of gender variation only significantly different at the upper peripheral measurement site such as the hand and fingers as opposed to lower extremities such as the ankle and feet.
“Dehghanojamahalleh et al. demonstrated variations in PPG morphology attributed to gender differences [105]. Interestingly, direct influence of gender variation was only significantly different at the upper peripheral measurement site such as the hand and fingers as opposed to lower extremities such as the ankle and feet.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [105]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Changes in Arterial Stiffness and Wave Reflection With Advancing Age in Healthy Men and Women
Mitchell, G. F., Parise, H., Benjamin, E. J., Larson, M. G., Keyes, M. J., Vita, J. A., Vasan, R. S., & Levy, D. A. (2004) · Hypertension · doi:10.1161/01.hyp.0000128420.01881.aa · Cited by 1,507 · see citing works
Body mass index as a measure of body fatness: age- and sex-specific prediction formulas
Deurenberg, P., Weststrate, J., & Seidell, J. C. (1991) · British Journal of Nutrition · doi:10.1079/bjn19910073 · Cited by 1,397 · see citing works
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · see citing works
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621 · see citing works
Benetos, A. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)03029-7 · Cited by 487 · see citing works
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 472 · see citing works
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z., & Poon, C. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 411 · see citing works
Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2015) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2015.7168806 · Cited by 351 · see citing works
Pulse transit time: an appraisal of potential clinical applications
Smith, R., ARGOD, J., Pépin, J., & Levy, P. A. (1999) · Thorax · doi:10.1136/thx.54.5.452 · Cited by 318 · see citing works
Elgendi, M., Norton, I., Brearley, M. B., Abbott, D., & Schuurmans, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076585 · Cited by 282 · see citing works
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202 · see citing works
Sex is a potent modifier of the cardiovascular system
Leinwand, L. A. (2003) · Journal of Clinical Investigation · doi:10.1172/jci19429 · Cited by 190 · see citing works
Arterial Stiffness and Wave Reflection
Russo, C. A., Jin, Z., Palmieri, V., Homma, S., Rundek, T., Elkind, M. S. V., Sacco, R. L., & Tullio, M. R. D. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.191148 · Cited by 181 · see citing works
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179 · see citing works
Relation between heart rate and pulse transit time during paced respiration
Drinnan, M. J., Allen, J., & Murray, A. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/3/301 · Cited by 169 · see citing works
Sex is a potent modifier of the cardiovascular system
Leinwand, L. A. (2003) · Journal of Clinical Investigation · doi:10.1172/jci200319429 · Cited by 161 · see citing works
A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time
Buxi, D., Redouté, J., & Yuce, M. R. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/r1 · Cited by 140 · see citing works
Allen, J., Oates, C. P., Lees, T. A., & Murray, A. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/018 · Cited by 112 · see citing works
Allen, J., & Murray, A. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/3/303 · Cited by 93 · see citing works
Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
Allen, J., & Murray, A. (2000) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20000846 · Cited by 76 · see citing works
Rajala, S., Lindholm, H., & Taipalus, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac7ac · Cited by 70 · see citing works
Blood flow measurements at different depths using photoplethysmography and laser Doppler techniques
Bergstrand, S., Lindberg, L. G., Ek, A., Lindén, M., & Lindgren, M. (2009) · Skin Research and Technology · doi:10.1111/j.1600-0846.2008.00337.x · Cited by 57 · see citing works
Pulse wave transit time for monitoring respiration rate
Johansson, A., Ahlstrom, C. H. G., Länne, T., & Ask, P. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0064-y · Cited by 38 · see citing works
Sex differences in cardiovascular function
Kolář, F., & Ošťádal, B. (2013) · Acta Physiologica · doi:10.1111/apha.12057 · Cited by 28 · see citing works
Sun, S., Peeters, W. H., Bezemer, R., Long, X., Paulussen, I., Aarts, R. M., & Noordergraaf, G. J. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-0140-5 · Cited by 26 · see citing works
Guajardo, I., Ayer, A., Johnson, A. D., Ganz, P., Mills, C., Donovan, C., Scherzer, R., Shah, S. J., Peralta, C. A., & Dubin, R. F. (2018) · Hemodialysis International · doi:10.1111/hdi.12544 · Cited by 21 · see citing works
Muehlsteff, J., Bresch, E., Schmitt, L., Gelissen, J., & Bingley, P. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592213 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Mühlen, J. M., Stang, J. S., Skovgaard, E. L., Júdice, P. B., Molina‐García, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 118 · see citing works
Finnegan, E., Davidson, S. M., Harford, M., Watkinson, P., Tarassenko, L., & Villarroel, M. (2023) · Scientific Reports · doi:10.1038/s41598-022-27170-2 · Cited by 83 · see citing works
Zhang, T., Ye, Z., Mahdad, A. T., Akanda, M. M. R. R., Shi, C., Wang, Y., Saxena, N., & Chen, Y. J. (2023) · ACM SIGSAC Conference on Computer and Communications Security (CCS) · doi:10.1145/3576915.3623102 · Cited by 26 · see citing works
Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life
Moscato, S., Palmerini, L., Palumbo, P., & Chiari, L. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.912353 · Cited by 20 · see citing works
Wu, Z., Li, X., Feng, Z., Wan, C., Ya, L., Li, T., Yang, Q., Liu, X., Ren, M., Li, J., et al. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202629 · Cited by 19 · see citing works
Blood pressure monitoring with piezoelectric bed sensor systems
Xing, X., Li, H., Chen, Q., Jiang, C., & Dong, W. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105479 · Cited by 18 · see citing works
Ferreira, A. F., Silva, H., Alves, H., Marques, N., & Fred, A. L. N. (2023) · Sensors · doi:10.3390/s23020620 · Cited by 17 · see citing works
Cortical thinning is associated with brain pulsatility in older adults: An MRI and NIRS study
Mohammadi, H., Peng, K., Kassab, A., Nigam, A., Bherer, L., Lesage, F., & Joanette, Y. (2021) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2021.05.002 · Cited by 15 · see citing works
Tran, K. T., Tran, T. T. T., Huynh, D. N., Le, N. K., Le, C. D., Mai, H. X., Linh, H. Q., & Nguyen, T.-L. (2025) · Sensors · doi:10.3390/s25216708 · Cited by 12 · see citing works
Marzano‐Felisatti, J. M., Lucca, L. D., Priego‐Quesada, J. I., & Pino‐Ortega, J. (2024) · Applied Sciences · doi:10.3390/app142411872 · Cited by 9 · see citing works
Badiola, I., Balaji, S., Silva, D., Blažek, V., Leonhardt, S. K., & Lueken, M. (2025) · Sensors · doi:10.3390/s25237176 · Cited by 7 · see citing works
SigD: A Cross-Session Dataset for PPG-based User Authentication in Different Demographic Groups
Li, L., Chen, C., Pan, L., Zhang, J., & Xiang, Y. (2023) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn54540.2023.10192018 · Cited by 7 · see citing works
Mansourinezhad, P., Ahmadi, M. M., & Mohammadzade, H. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3282590 · Cited by 5 · see citing works
Photoplethysmography (PPG) Signal-Based Chronological Age Estimation Algorithm
Asyrafi, H., Sunarno, S., Faridah, F., Waruwu, M. M., & Wijaya, R. H. (2022) · International Conference of Science and Information Technology in Smart Administration (ICSINTESA) · doi:10.1109/icsintesa56431.2022.10041494 · Cited by 5 · see citing works
Remote photoplethysmography based on reflected light angle estimation
Fan, X., Liu, F., Zhang, J., Gao, T., Fan, Z., Huang, Z., Xue, W., & Zhang, J. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad2f5d · Cited by 4 · see citing works
Luo, W., Guo, H., Li, X., Yang, J., Ding, Y., Wang, X., Song, Q., Wang, C., Sun, H., Zhang, W., et al. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202500089 · Cited by 3 · see citing works
Dehghanojamahalleh, S., Gamage, P. T., Ahmed, M., Petersen, C., Matthew, B. P., Hyacinth, K., Weerasinghe, Y., Subasi, E., Subasi, M. M., & Kaya, M. (2025) · BioMedInformatics · doi:10.3390/biomedinformatics5020024 · Cited by 2 · see citing works
Self-citationMonte Carlo simulation-based analysis of unobtrusive PPG monitoring through clothes
Badiola, I., Linschmann, O., Willms, L., Blažek, V., Leonhardt, S. K., & Lueken, M. (2023) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms58004.2023.00318 · Cited by 1 · see citing works
Meta-Analysis of Randomized Clinical Trials on the Speed of Pulse Wave Propagation
Gharamyan, B. G. (2023) · BIOPHYSICS · doi:10.1134/s0006350923060088
Meta-analysis of randomized clinical trials on the speed of pulse wave propagation
Gharamyan, B. G. (2023) · Биофизика · doi:10.31857/s0006302923060182
Exploring Gender-Related Variations in Photoplethysmography
Lombardi, S., Francia, P., & Bocchi, L. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782441
Foronda-Pascual, D., Cámara, C., & Lopez, P. P. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1616770
Han, X., Li, E. X., Volodarskiy, A., Slotwiner, D. J., & Zhao, Y. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae66c7
Sato, S., & Nakayama, S. (2026) · Biomedical Engineering Advances · doi:10.1016/j.bea.2026.100220
- Authors
- Dehghanojamahalleh, S., & Kaya, M.
- Affiliations
- Florida Institute of Technology (US)
- Corresponding author
- Kaya, Mehmet
- Venue
- IEEE Journal of Translational Engineering in Health and Medicine
- Published
- 2019
- Volume
- 7
- Pages
- 1-7
- ISSN
- 2168-2372 (ISSN-L)
- PMC
- PMC6752633
- OpenAlex
- W2970804427
- Cited by
- 25
- References
- 27
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 3 · 2023: 10 · 2022: 2 · 2021: 3
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- IEEE Journal of Translational Engineering in Health and Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Florida Institute of Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- sex differences, photoplethysmography, finger PPG, pulse transit time, pulse arrival time, cardiovascular function, cardiovascular risk, anthropometric parameters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review