The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
Abstract
This paper presents efficient denoising and lossy compression schemes for electrocardiogram (ECG) signals based on a modified extended Kalman filter (EKF) structure. We have used a previously introduced two-dimensional EKF structure and modified its governing equations to be extended to a 17-dimensional case. The new EKF structure is used not only for denoising, but also for compression, since it provides estimation for each of the new 15 model parameters. Using these specific parameters, the signal is reconstructed with regard to the dynamical equations of the model. The performances of the proposed method are evaluated using standard denoising and compression efficiency measures. For denosing, the SNR improvement criterion is used, while for compression, we have considered the compression ratio (CR), the percentage area difference (PAD), and the weighted diagnostic distortion (WDD) measure. Several Massachusetts Institute of Technology-Beth Israel Deaconess Medical Center (MIT-BIH) ECG databases are used for performance evaluation. Simulation results illustrate that both applications can contribute to and enhance the clinical ECG data denoising and compression performance. For denoising, an average SNR improvement of 10.16 dB was achieved, which is 1.8 dB more than the next benchmark methods such as MABWT or EKF2. For compression, the algorithm was extended to include more than five Gaussian kernels. Results show a typical average CR of 11.37:1 with WDD << 1.73%. Consequently, the proposed framework is suitable for a hybrid system that integrates these algorithmic approaches for clean ECG data storage or transmission scenarios with high output SNRs, high CRs, and low distortions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De-noising by soft-thresholding
Donoho, D. L. (1995) · IEEE Transactions on Information Theory · doi:10.1109/18.382009 · Cited by 9,619
Fundamentals of statistical signal processing: Estimation theory
Prasad, K. V. (1994) · Control Engineering Practice · doi:10.1016/0967-0661(94)90195-3 · Cited by 7,902
Fundamentals Of Statistical Signal Processing
Kay, S. (2001) · International Linear Collider · Cited by 3,642
An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds
Coleman, T. F., & Li, Y. (1996) · SIAM Journal on Optimization · doi:10.1137/0806023 · Cited by 3,320
A dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224
Coleman, T. F., & Li, Y. (1994) · Mathematical Programming · doi:10.1007/bf01582221 · Cited by 1,135
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection
Thakor, N. V., & Zhu, Y.-S. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83591 · Cited by 885
ECG data compression techniques-a unified approach
Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52340 · Cited by 681
Coleman, T. F., & Li, Y. (1992) · Cited by 551
Cited by
An Ultra Low Power Personalizable Wrist Worn ECG Monitor Integrated With IoT Infrastructure
Beach, C., Krachunov, S., Pope, J., Fafoutis, X., Piechocki, R. J., Craddock, I., & Casson, A. J. (2018) · IEEE Access · doi:10.1109/access.2018.2864675 · Cited by 91
Metadata
- Authors
- Sayadi, O., & Shamsollahi, M. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-09
- Volume
- 55
- Issue
- 9
- Pages
- 2240-2248
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2104750904
- Cited by
- 254
- References
- 22
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure. https://app.cochat.ai/papers/10.1109/tbme.2008.921150
- The paper
- Sayadi, O., & Shamsollahi, M. B. (2008). ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2008.921150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.