Nonstationary Brain Source Separation for Multiclass Motor Imagery
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper describes a method to recover task-related brain sources in the context of multiclass brain--computer interfaces (BCIs) based on noninvasive EEG. We extend the method joint approximate diagonalization (JAD) for spatial filtering using a maximum likelihood framework. This generic formulation: 1) bridges the gap between the common spatial patterns (CSPs) and blind source separation of nonstationary sources; and 2) leads to a neurophysiologically adapted version of JAD, accounting for the successive activations/deactivations of brain sources during motor imagery (MI) trials. Using dataset 2a of BCI Competition IV (2008) in which nine subjects were involved in a four-class two-session MI-based BCI experiment, a quantitative evaluation of our extension is provided by comparing its performance against JAD and CSP in the case of cross-validation, as well as session-to-session transfer. While JAD, as already proposed in other works, does not prove to be significantly better than classical one-versus-rest CSP, our extension is shown to perform significantly better than CSP for cross-validated and session-to-session performance. The extension of JAD introduced in this paper yields among the best session-to-session transfer results presented so far for this particular dataset; thus, it appears to be of great interest for real-life BCIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“THE AIM of noninvasive brain–computer interfaces (BCIs) is to establish a direct communication pathway between human intentions and electronic devices [1].”
BackgroundSelf-citationEvent-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 1×
“Second, as shown in [24], event-related desynchro-”
Self-citationA review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Self-citationOptimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“For instance, the local, sparse, and spectral versions of the CSP algorithm have been proposed and proved useful in some cases to increase classification rates [8]–[10] (see [11] for a review of the different CSP principles).”
MethodMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Self-citationDesigning optimal spatial filters for single-trial EEG classification in a movement task
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00038-8 · Cited by 846
Self-citation
Cited by
Multiclass Brain–Computer Interface Classification by Riemannian Geometry
Barachant, A., Bonnet, S., Congedo, M., & Jutten, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2172210 · Cited by 878
Self-citationTransfer Learning: A Riemannian Geometry framework with applications to Brain-Computer Interfaces
Zanini, P., Congedo, M., Jutten, C., Said, S., & Berthoumieu, Y. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2742541 · Cited by 412
“The standard classification technique consists of two operational stages [9], [18].”
BackgroundMethodInfluentialSelf-citationProbabilistic Common Spatial Patterns for Multichannel EEG Analysis
Wu, W., Chen, Z., Gao, X., Li, Y., Brown, E. N., & Gao, S. (2015) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2014.2330598 · Cited by 194
“The connection between model (4) and CSP is revealed by the following theorem [3], [31], [39], [40]:”
A Plug&Play P300 BCI Using Information Geometry
Barachant, A., & Congedo, M. (2014) · arXiv · doi:10.48550/arxiv.1409.0107 · Cited by 102
Self-citation
Metadata
- Authors
- Gouy-Pailler, C., Congedo, M., Brunner, C., Jutten, C., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-02
- Volume
- 57
- Issue
- 2
- Pages
- 469-478
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2161046211
- Cited by
- 115
- References
- 6
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.