CoChat

An Online Self-Tunable Method to Denoise CGM Sensor Data

Facchinetti, A., Sparacino, G., Cobelli, C. · 2010 · IEEE Transactions on Biomedical Engineering
Cited by 62

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Continuous glucose monitoring (CGM) devices can be very useful in diabetes management. Unfortunately, their use in online applications, e.g., for hypo/hyperalert generation, is made difficult by random noise measurement. Remarkably, the SNR of CGM data varies with the sensor and with the individual. As a consequence, approaches in which filter parameters are not allowed to adapt to the current SNR are likely to be suboptimal. In this paper, we present a new online methodology to reduce noise in CGM signals by a Kalman filter (KF), whose unknown parameters are adjusted in a given individual by a stochastically based smoothing criterion exploiting data of a burn-in interval. The performance of the new KF approach is quantitatively assessed on Monte Carlo simulations and 24 real CGM datasets. Our results are compared with those obtained by a moving-average (MA) filtering approach with fixed parameters currently in use in likely all commercial CGM devices. Results show that the new KF approach performs much better than MA. For instance, on real data, for comparable signal denoising, the delay introduced by KF is about 35% less than that obtained by MA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2009.2033264

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 62

Metadata

Authors
Facchinetti, A., Sparacino, G., & Cobelli, C.
Venue
IEEE Transactions on Biomedical Engineering
Published
2010-03
Volume
57
Issue
3
Pages
634-641
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2121201523
Cited by
62
References
2
FWCI
4.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.