Motion Artifact Removal for Functional Near Infrared Spectroscopy: A Comparison of Methods
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Near infrared spectroscopy (NIRS) is rapidly gaining popularity for functional brain imaging. It is well suited to studies of patients or children; however, in these populations particularly, motion artifacts can present a problem. Here, we propose the use of imaging channels with negligible distance between light source and detector to detect subject motion, without the need for an additional motion sensor. Datasets containing deliberate motion artifacts were obtained from three subjects. Motion artifacts could be detected in the signal from the co-located channels with a minimum sensitivity of 0.75 and specificity of 0.98. Five techniques for removing motion artifact from the functional signals were compared, namely two-input recursive least squares (RLS) adaptive filtering, wavelet-based filtering, independent component analysis (ICA), and two-channel and multiple-channel regression. In most datasets, the median change in SNR across all channels was the greatest using ICA or multiple-channel regression. RLS adaptive filtering produced the smallest increase in SNR. Where sharp spikes were present, wavelet filtering produced the largest SNR increase. ICA and multiple-channel regression are promising ways to reduce motion artifact in functional NIRS without requiring time-consuming manual techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Cited by
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Brigadoi, S., Ceccherini, L., Cutini, S., Scarpa, F., Scatturin, P., Selb, J., Gagnon, L., Boas, D. A., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.082 · Cited by 557
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
“The analysis by Robertson et al. (2010) shows that short separation channels can also be very useful in the reduction of motion artifacts using adaptive filtering techniques.”
BackgroundMethodInfluentialChen, W.-L., Wagner, J., Heugel, N., Sugar, J., Lee, Y.-W., Conant, L., Malloy, M., Heffernan, J., Quirk, B., Zinos, A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00724 · Cited by 382
Wavelet Based Empirical Approach to Mitigate the Effect of Motion Artifacts from EEG Signal
Shukla, S., Roy, V., & Prakash, A. (2020) · 2020 IEEE 9th International Conference on Communication Systems and Network Technologies (CSNT) · doi:10.1109/csnt48778.2020.9115761 · Cited by 333
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Sweeney, K. T., McLoone, S. F., & Ward, T. E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 300
Stalin, S., Roy, V., Shukla, P. K., Zaguia, A., Khan, M. M., Shukla, P. K., & Jain, A. (2021) · Mathematical Problems in Engineering · doi:10.1155/2021/2942808 · Cited by 290
Neurobiological basis of head motion in brain imaging
Zeng, L.-L., Wang, D., Fox, M. D., Sabuncu, M., Hu, D., Ge, M., Buckner, R. L., & Liu, H. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317424111 · Cited by 285
Quaresima, V., Bisconti, S., & Ferrari, M. (2012) · Brain and Language · doi:10.1016/j.bandl.2011.03.009 · Cited by 276
Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
“…et al 2006c), PCA truncation (Wilcox et al 2005), local and global assessment of the variance (Holper et al 2009, White et al 2009), ICA over co-located channels (Robertson et al 2010), Kalman filtering (Izzetoglu et al 2010) and exploiting negative correlations among Hb species (Cui et al 2010).”
MethodNozawa, T., Sakaki, K., Ikeda, S., Jeong, H., Yamazaki, S., Kawata, K. H. D. S., Kawata, N. Y. D. S., Sasaki, Y., Kulason, K., Hirano, K., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49257-z · Cited by 95
Yücel, M. A., Selb, J., Boas, D. A., Cash, S. S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.054 · Cited by 86
“…the minimization of motion artifacts: methods which require some external measurement of the movements of the subject (such as adaptive filtering (Robertson et al., 2010; Zhang et al., 2007)) and methods that do not require extra measurements (such as principal component analysis, Kalman…”
Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners
Borges, N. R., & Driller, M. W. (2016) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001307 · Cited by 59
“Additionally, there is a high prevalence of cycle ergometer studies in existing research which is most likely a result of the possible increase in signal noise owing to movement artifact of the NIRS leads while running (25).”
BackgroundMovement artefact removal from NIRS signal using multi-channel IMU data
Siddiquee, M. R., Marquez, J. S., Atri, R., Ramon, R., Perry Mayrand, R., & Bai, O. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0554-9 · Cited by 33
Metadata
- Authors
- Robertson, F. C., Douglas, T. S., & Meintjes, E. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-06
- Volume
- 57
- Issue
- 6
- Pages
- 1377-1387
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2108431768
- Cited by
- 148
- References
- 2
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.