Application of Covariate Shift Adaptation Techniques in Brain–Computer Interfaces
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A phenomenon often found in session-to-session transfers of brain-computer interfaces (BCIs) is nonstationarity. It can be caused by fatigue and changing attention level of the user, differing electrode placements, varying impedances, among other reasons. Covariate shift adaptation is an effective method that can adapt to the testing sessions without the need for labeling the testing session data. The method was applied on a BCI Competition III dataset. Results showed that covariate shift adaptation compares favorably with methods used in the BCI competition in coping with nonstationarities. Specifically, bagging combined with covariate shift helped to increase stability, when applied to the competition dataset. An online experiment also proved the effectiveness of bagged-covariate shift method. Thus, it can be summarized that covariate shift adaptation is helpful to realize adaptive BCI systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Improving predictive inference under covariate shift by weighting the log-likelihood function
Shimodaira, H. (2000) · Journal of Statistical Planning and Inference · doi:10.1016/s0378-3758(00)00115-4 · Cited by 1,678
Vidaurre, C., Schloogl, A., Cabeza, R., Scherer, R., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873542 · Cited by 195
An experimental evaluation of ensemble methods for EEG signal classification
Sun, S., Zhang, C., & Zhang, D. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.06.018 · Cited by 130
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Some unsupervised methods rely on techniques for co-adaptive learning of user and machine [218,219] or covariate shift adaptation [220].”
MethodJayaram, V., Alamgir, M., Altun, Y., Scholkopf, B., & Grosse-Wentrup, M. (2016) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2015.2501545 · Cited by 468
“In addition to their results, several other authors have also reported improvements in BCI decoding performance by using similar techniques for covariate shift adaptation [27]–[29].”
ResultIntra- and Inter-subject Variability in EEG-Based Sensorimotor Brain Computer Interface: A Review
Saha, S., & Baumert, M. (2020) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2019.00087 · Cited by 325
Performance variation in motor imagery brain–computer interface: A brief review
Ahn, M., & Jun, S. C. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.033 · Cited by 316
Toward Unsupervised Adaptation of LDA for Brain–Computer Interfaces
Vidaurre, C., Kawanabe, M., von Bünau, P., Blankertz, B., & Müller, K. R. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2093133 · Cited by 296
Metadata
- Authors
- Li, Y., Kambara, H., Koike, Y., & Sugiyama, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-06
- Volume
- 57
- Issue
- 6
- Pages
- 1318-1324
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2163310171
- Cited by
- 134
- References
- 4
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.