Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Quantitative Falls Risk Assessment Using the Timed Up and Go Test

Greene, Barry. R., O'Donovan, Alan, Romero-Ortuno, Roman, Cogan, Lisa, Scanaill, Cliodhna Ni, Kenny, Rose A.·2010·IEEE Transactions on Biomedical Engineering

Abstract

Falls are a major problem in older adults worldwide with an estimated 30% of elderly adults over 65 years of age falling each year. The direct and indirect societal costs associated with falls are enormous. A system that could provide an accurate automated assessment of falls risk prior to falling would allow timely intervention and ease the burden on overstretched healthcare systems worldwide. An objective method for assessing falls risk using body-worn kinematic sensors is reported. The gait and balance of 349 community-dwelling elderly adults was assessed using body-worn sensors while each patient performed the "timed up and go" (TUG) test. Patients were also evaluated using the Berg balance scale (BBS). Of the 44 reported parameters derived from body-worn kinematic sensors, 29 provided significant discrimination between patients with a history of falls and those without. Cross-validated estimates of retrospective falls prediction performance using logistic regression models yielded a mean sensitivity of 77.3% and a mean specificity of 75.9%. This compares favorably to the cross-validated performance of logistic regression models based on the time taken to complete the TUG test (manually timed TUG) and the Berg balance score. These models yielded mean sensitivities of 58.0% and 57.8%, respectively, and mean specificities of 64.8% and 64.2%, respectively. Results suggest that this method offers an improvement over two standard falls risk assessments (TUG and BBS) and may have potential for use in supervised assessment of falls risk as part of a longitudinal monitoring protocol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2010.2083659

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 261

Metadata

Authors
Greene, B. R., O'Donovan, A., Romero-Ortuno, R., Cogan, L., Scanaill, C. N., & Kenny, R. A.
Venue
IEEE Transactions on Biomedical Engineering
Published
2010-12
Volume
57
Issue
12
Pages
2918-2926
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2144954419
Cited by
261
References
25
FWCI
38.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.