The Integral Pulse Frequency Modulation Model With Time-Varying Threshold: Application to Heart Rate Variability Analysis During Exercise Stress Testing
The DOI matches its Crossref record.
Abstract
In this paper, an approach for heart rate variability analysis during exercise stress testing is proposed based on the integral pulse frequency modulation (IPFM) model, where a time-varying threshold is included to account for the nonstationary mean heart rate. The proposed technique allows the estimation of the autonomic nervous system (ANS) modulating signal using the methods derived for the IPFM model with constant threshold plus a correction, which is shown to be needed to take into account the time-varying mean heart rate. On simulations, this technique allows the estimation of the ANS modulation on the heart from the beat occurrence time series with lower errors than the IPFM model with constant threshold (1.1% ± 1.3% versus 15.0% ± 14.9%). On an exercise stress testing database, the ANS modulation estimated by the proposed technique is closer to physiology than that obtained from the IPFM model with constant threshold, which tends to overestimate the ANS modulation during the recovery and underestimate it during the initial rest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Drowsiness detection using heart rate variability
Vicente, J., Laguna, P., Bartra, A., & Bailón, R. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1448-7 · Cited by 255
Self-citationHernando, D., Roca, S., Sancho, J., Alesanco, Á., & Bailón, R. (2018) · Sensors · doi:10.3390/s18082619 · Cited by 222
“Finally, the modulating signal, which is assumed to represent the ANS modulation on the sinoatrial node, was obtained as m̂(n) = dHRV(n)/dHRM(n) [30].”
MethodSelf-citationHernando, A., Lazaro, J., Gil, E., Arza, A., Garzon, J. M., Lopez-Anton, R., de la Camara, C., Laguna, P., Aguilo, J., & Bailon, R. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2553578 · Cited by 179
Self-citationTuron, M., Fernandez-Gonzalo, S., Jodar, M., Gomà, G., Montanya, J., Hernando, D., Bailón, R., de Haro, C., Gomez-Simon, V., Lopez-Aguilar, J., et al. (2017) · Annals of Intensive Care · doi:10.1186/s13613-017-0303-4 · Cited by 56
“Since the mean heart rate is not constant (it evolves continuously in challenging situations, such as physical and mental effort, especially in critically ill patients), the HRV signal was corrected by the time-varying mean heart rate [33], yielding the modulating signal which, according to the IPFM model, represents…”
MethodSelf-citation(2011) · Computing in cardiology
Metadata
- Authors
- Bailón, R., Laouini, G., Grao, C., Orini, M., Laguna, P., & Meste, O.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-03
- Volume
- 58
- Issue
- 3
- Pages
- 642-652
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2151837563
- Cited by
- 109
- References
- 0
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).