CoChat

Inclusion of Respiratory Frequency Information in Heart Rate Variability Analysis for Stress Assessment

Hernando, Alberto, Lazaro, Jesus, Gil, Eduardo, Arza, Adriana, Garzon, Jorge Mario, Lopez-Anton, Raul, de la Camara, Concepcion, Laguna, Pablo, Aguilo, Jordi, Bailon, Raquel · 2016 · IEEE Journal of Biomedical and Health Informatics
Cited by 179

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Respiratory rate and heart rate variability (HRV) are studied as stress markers in a database of young healthy volunteers subjected to acute emotional stress, induced by a modification of the Trier Social Stress Test. First, instantaneous frequency domain HRV parameters are computed using time-frequency analysis in the classical bands. Then, the respiratory rate is estimated and this information is included in HRV analysis in two ways: 1) redefining the high-frequency (HF) band to be centered at respiratory frequency; 2) excluding from the analysis those instants where respiratory frequency falls within the low-frequency (LF) band. Classical frequency domain HRV indices scarcely show statistical differences during stress. However, when including respiratory frequency information in HRV analysis, the normalized LF power as well as the LF/HF ratio significantly increase during stress ( p-value 0.05 according to the Wilcoxon test), revealing higher sympathetic dominance. The LF power increases during stress, only being significantly different in a stress anticipation stage, while the HF power decreases during stress, only being significantly different during the stress task demanding attention. Our results support that joint analysis of respiration and HRV obtains a more reliable characterization of autonomic nervous response to stress. In addition, the respiratory rate is observed to be higher and less stable during stress than during relax ( p-value 0.05 according to the Wilcoxon test) being the most discriminative index for stress stratification (AUC = 88.2 % ).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2016.2553578

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 179

Metadata

Authors
Hernando, A., Lazaro, J., Gil, E., Arza, A., Garzon, J. M., Lopez-Anton, R., de la Camara, C., Laguna, P., Aguilo, J., & Bailon, R.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2016-07
Volume
20
Issue
4
Pages
1016-1025
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2339153830
Cited by
179
References
8
FWCI
16.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inclusion of Respiratory Frequency Information in Heart Rate Variability Analysis for Stress Assessment. https://app.cochat.ai/papers/10.1109/jbhi.2016.2553578
The paper
Hernando, A., Lazaro, J., Gil, E., Arza, A., Garzon, J. M., Lopez-Anton, R., de la Camara, C., Laguna, P., Aguilo, J., & Bailon, R. (2016). Inclusion of Respiratory Frequency Information in Heart Rate Variability Analysis for Stress Assessment. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2016.2553578

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.