The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Abstract
A novel dry foam-based electrode for long-term EEG measurement was proposed in this study. In general, the conventional wet electrodes are most frequently used for EEG measurement. However, they require skin preparation and conduction gels to reduce the skin-electrode contact impedance. The aforementioned procedures when wet electrodes were used usually make trouble to users easily. In order to overcome the aforesaid issues, a novel dry foam electrode, fabricated by electrically conductive polymer foam covered by a conductive fabric, was proposed. By using conductive fabric, which provides partly polarizable electric characteristic, our dry foam electrode exhibits both polarization and conductivity, and can be used to measure biopotentials without skin preparation and conduction gel. In addition, the foam substrate of our dry electrode allows a high geometric conformity between the electrode and irregular scalp surface to maintain low skin-electrode interface impedance, even under motion. The experimental results presented that the dry foam electrode performs better for long-term EEG measurement, and is practicable for daily life applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248
Cited by
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Self-citationIdentifying Stable Patterns over Time for Emotion Recognition from EEG
Zheng, W.-L., Zhu, J.-Y., & Lu, B.-L. (2019) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2712143 · Cited by 990
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 828
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Metadata
- Authors
- Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1200-1207
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2109073090
- Cited by
- 336
- References
- 1
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement. https://app.cochat.ai/papers/10.1109/tbme.2010.2102353
- The paper
- Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011). Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2010.2102353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.